LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
CTL72
Message The foreign configuration overflow has occurred on
arg1
.
Arguments
arg1 =
Controller name
Detailed
Description
There is too much foreign configuration data to be imported in one attempt.
Recommended
Response Action
Import these foreign configurations in multiple attempts.
Category Storage
SubCategory CTL = Storage Contr
Severity Severity 2 (Warning)
Trap/EventID 4330
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
CTL73
Message Foreign configuration is imported only partially. Some configurations failed to import on
arg1
.
Arguments
arg1 =
Controller name
Detailed
Description
This alert is provided for informational purposes.
Recommended
Response Action
No response action is required.
Category Storage
SubCategory CTL = Storage Contr
Severity Severity 3 (Informational)