Arguments
arg1 =
number
Detailed
Description
The fabric type for the IOM and mezzanine cards must match. Once an IOM or mezzanine card
is inserted into the chassis, the fabric type is then set for the CMC and the CMC will ensure that
all subsequent IOMs and mezzanine cards match.
Recommended
Response Action
Check chassis fabric type in CMC GUI and compare to the type of IOM or mezzanine card.
Category System Health
SubCategory HWC = Hardware Config
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
HWC2009
Message Mezzanine card
arg1
is installed correctly.
Arguments
arg1 =
number
Detailed
Description
None
Recommended
Response Action
No response action is required.
Category System Health
SubCategory HWC = Hardware Config
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
264
Vista de pagina 263
1 2 ... 259 260 261 262 263 264 265 266 267 268 269 ... 930 931

Comentarios a estos manuales

Sin comentarios