Dell Chassis Management Controller Version 1.0 for PowerEdge VRTX Guía de usuario Pagina 263

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 931
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 262
HWC4014
Message Link Tuning data successfully updated.
Detailed
Description
None
Recommended
Response Action
No response action is required.
Category System Health
SubCategory HWC = Hardware Config
Severity Severity 3 (Informational)
Trap/EventID 2331
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
HWC4015
Message Link Tuning error detected.
Detailed
Description
CMC has old firmware and does not recognize the new device which has requested link tuning
information. After updating the firmware the CMC will recognize the device.
Recommended
Response Action
Update the CMC firmware. If the problem persists, contact support.
Category System Health
SubCategory HWC = Hardware Config
Severity Severity 1 (Critical)
Trap/EventID 2329
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
HWC2008
Message A fabric mismatch detected for mezzanine card
arg1
.
263
Vista de pagina 262
1 2 ... 258 259 260 261 262 263 264 265 266 267 268 ... 930 931

Comentarios a estos manuales

Sin comentarios