Dell Chassis Management Controller Version 1.0 for PowerEdge VRTX Guía de usuario Pagina 385

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 931
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 384
SubCategory MEM = Memory
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
MEM1003
Message Memory device at location
arg1
failed to transition to in test.
Arguments
arg1 =
location
Detailed
Description
None
Recommended
Response Action
Re-install the memory component. If the problem continues, contact support.
Category System Health
SubCategory MEM = Memory
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
MEM1004
Message Memory device at location
arg1
is powered off.
Arguments
arg1 =
location
Detailed
Description
None
Recommended
Response Action
No response action is required.