Dell Chassis Management Controller Version 1.0 for PowerEdge VRTX Guía de usuario Pagina 355

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 931
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 354
20
LNK Event Messages
LNK8500
Message Network link to servers in slot
arg1
IOM
arg2
port
arg3
is down
Arguments
arg1 =
slot id
arg2 =
iom id
arg3 =
port id
Detailed
Description
Internal sled network connection is down
Recommended
Response Action
Remove and re-insert the sled
Category System Health
SubCategory LNK = Link Status
Severity Severity 1 (Critical)
Trap/EventID 2249
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#EMAIL Alert;#LCD;#LC Log;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
LNK8501
Message Network link to servers in slot
arg1
IOM
arg2
port
arg3
is up
Arguments
arg1 =
slot id
arg2 =
iom id
arg3 =
port id
Detailed
Description
Internal sled network connection is up
Recommended
Response Action
No response action is required.