Dell Chassis Management Controller Version 1.0 for PowerEdge VRTX Guía de usuario Pagina 417

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 931
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 416
Detailed
Description
Either the BIOS, BMC/iDRAC, or LOM firmware is out of date and does not support
FlexAddress.
Recommended
Response Action
Update BIOS, BMC/iDRAC, and LOM firmware. If problem persists please contact customer
support.
Category System Health
SubCategory PCI = PCI Device
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PCI3001
Message Device option ROM on embedded NIC was successfully updated.
Detailed
Description
None
Recommended
Response Action
No response action is required.
Category System Health
SubCategory PCI = PCI Device
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PCI3002
Message Failed to program virtual MAC address on a component at bus
arg1
device
arg2
function
arg3
.
Arguments
arg1 =
bus
arg2 =
device
arg3 =
func
417