Dell Chassis Management Controller Version 1.0 for PowerEdge VRTX Guía de usuario Pagina 413

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 931
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 412
Trap/EventID FALSE
LCD Message Fatal error on slot <number>. Reseat PCI card
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PCI1360
Message A bus fatal error was detected on a component at slot
arg1
.
Arguments
arg1 =
number
Detailed
Description
System performance may be degraded, or system may fail to operate.
Recommended
Response Action
Cycle input power, update component drivers, if device is removable, re-install the device.
Category System Health
SubCategory PCI = PCI Device
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message Bus fatal error on slot <number>. Reseat PCI card
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PCI1322
Message Bus performance degraded for a component at bus
arg1
device
arg2
function
arg3
.
Arguments
arg1 =
bus
arg2 =
device
arg3 =
func
Detailed
Description
System performance may be degraded. The bus is not operating at maximum speed or width.
Recommended
Response Action
Cycle input power, update component drivers, if device is removable, re-install the device.
Category System Health
413
Vista de pagina 412
1 2 ... 408 409 410 411 412 413 414 415 416 417 418 ... 930 931

Comentarios a estos manuales

Sin comentarios