Dell Chassis Management Controller Version 1.0 for PowerEdge VRTX Guía de usuario Pagina 544

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 931
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 543
SubCategory PSU = Power Supply
Severity Severity 1 (Critical)
Trap/EventID 2185
LCD Message Output over current fault detected on PSU <number>. Check PSU.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
PSU0043
Message An output under current fault detected on power supply
arg1
.
Arguments
arg1 =
number
Detailed
Description
None
Recommended
Response Action
1) Remove the power supply input cord and then remove power supply. 2) Re-install the power
supply and then re-install the power supply cord. 3) If the issue persists, contact technical
support. Refer to the product documentation to choose a convenient contact method.
Category System Health
SubCategory PSU = Power Supply
Severity Severity 1 (Critical)
Trap/EventID 2185
LCD Message Output under current fault detected on PSU <number>. Check PSU.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
PSU0044
Message Cannot obtain status information from power supply
arg1
.
Arguments
arg1 =
number
Detailed
Description
The power supply is operating but the system cannot get status information.
544
Vista de pagina 543
1 2 ... 539 540 541 542 543 544 545 546 547 548 549 ... 930 931

Comentarios a estos manuales

Sin comentarios