Dell Chassis Management Controller Version 1.0 for PowerEdge VRTX Guía de usuario Pagina 559

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 931
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 558
Detailed
Description
The chassis power cycle operation was initiated.
Recommended
Response Action
No response action is required.
Category Audit
SubCategory PWR = Power Usage
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
PWR8523
Message Completed chassis power cycle operation.
Detailed
Description
The chassis power cycle operation was completed.
Recommended
Response Action
No response action is required.
Category Audit
SubCategory PWR = Power Usage
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
PWR8524
Message Redundancy was lost, while Server Performance Over Power Redundancy is enabled.
Detailed
Description
The redundancy was lost because the power requirement of the chassis exceeds the current
redundant policy.
Recommended
Response Action
No response action is required. Review the power requirements and determine if more PSUs
are needed to restore redundancy.
559