Dell Chassis Management Controller Version 1.0 for PowerEdge VRTX Guía de usuario Pagina 857

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 931
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 856
46
VDR Event Messages
VDR97
Message Patrol Read corrected a media error on
arg1
.
Arguments
arg1 =
VD Name
Detailed
Description
The Patrol Read task has encountered an error such as a bad disk block and remapped data to
correct the error.
Recommended
Response Action
No response action is required.
Category Storage
SubCategory VDR = Virtual Disk
Severity Severity 3 (Informational)
Trap/EventID 4355
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
VDR1
Message
arg1
failed.
Arguments
arg1 =
VD Name
Detailed
Description
A storage component such as a physical disk or an enclosure has failed. The failed component
may have been identified by the controller while performing a task such as a rescan or a check
consistency.
Recommended
Response Action
Replace the failed component. You can identify which component has failed by locating the
component that has a red "X" for its status. Perform a rescan after replacing the failed
component.
Category Storage
SubCategory VDR = Virtual Disk
857
Vista de pagina 856
1 2 ... 852 853 854 855 856 857 858 859 860 861 862 ... 930 931

Comentarios a estos manuales