Dell Chassis Management Controller Version 1.0 for PowerEdge VRTX Guía de usuario Pagina 407

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 931
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 406
Detailed
Description
System performance may be degraded.
Recommended
Response Action
Cycle input power, update component drivers, if device is removable re-install the device at the
next scheduled service time.
Category System Health
SubCategory PCI = PCI Device
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PCI1316
Message A bus uncorrectable error was detected on a component at bus
arg1
device
arg2
function
arg3
.
Arguments
arg1 =
bus
arg2 =
device
arg3 =
func
Detailed
Description
System performance may be degraded, or system may fail to operate.
Recommended
Response Action
Cycle input power, update component drivers, if device is removable, re-install the device.
Category System Health
SubCategory PCI = PCI Device
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
407
Vista de pagina 406
1 2 ... 402 403 404 405 406 407 408 409 410 411 412 ... 930 931

Comentarios a estos manuales

Sin comentarios