PDR84
Message
arg1
Security key has changed.
Arguments
arg1 =
physical disk
Detailed
Description
The Security key on a secure encrypted disk was activated.
Recommended
Response Action
No response action is required.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 3 (Informational)
Trap/EventID 4347
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
PDR85
Message Security subsystem errors detected for
arg1
.
Arguments
arg1 =
physical disk
Detailed
Description
Errors were detected with security related operations on the disk. The data on the disk might
not be retrieved or stored successfully. In addition, the security of the stored data might be at
risk.
Recommended
Response Action
Verify the disk is a Secure Encrypted Disk and is not locked. If it is not, replace the disk with a
Secure Encrypted Disk. See the storage hardware documentation for more information.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 1 (Critical)
Trap/EventID 4345
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log