Dell Chassis Management Controller Version 1.0 for PowerEdge VRTX Guía de usuario Pagina 415

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 931
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 414
Recommended
Response Action
Cycle input power, update component drivers, remove and re-install the device.
Category System Health
SubCategory PCI = PCI Device
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message Fatal IO error on bus <bus> device <device> function <func>. Contact support
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PCI2001
Message The component at bus
arg1
device
arg2
function
arg3
recovered from a fatal IO error.
Arguments
arg1 =
bus
arg2 =
device
arg3 =
func
Detailed
Description
None
Recommended
Response Action
No response action is required.
Category System Health
SubCategory PCI = PCI Device
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PCI2002
Message A fatal IO error detected on a component at slot
arg1
.
Arguments
arg1 =
number
415