Dell Chassis Management Controller Version 1.0 for PowerEdge VRTX Guía de usuario Pagina 312

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 931
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 311
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
IOV1002
Message The operation was not successful.
Detailed
Description
The operation did not complete successfully due to an exception from the instrumentation
layer.
Recommended
Response Action
Retry the operation. If the issue persists, reset CMC and retry the operation when the CMC has
completed restarting. The CMC may take 2 to 3 minutes to complete restarting.
Category Configuration
SubCategory IOV = IO Virtualization
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. None
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
IOV1003
Message Missing required parameter
arg1
.
Arguments
arg1 =
parameter name
Detailed
Description
One or more parameters identified in the message required for the method are missing.
Recommended
Response Action
Refer to the Dell Chassis PCI Management Profile document and provide the required
parameter.
Category Configuration
SubCategory IOV = IO Virtualization
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. None