Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PCI1350
Message A PCI system error was detected on a component at slot
arg1
.
Arguments
arg1 =
number
Detailed
Description
System performance may be degraded, or system may fail to operate.
Recommended
Response Action
Cycle input power, update component drivers, if device is removable, re-install the device.
Category System Health
SubCategory PCI = PCI Device
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message PCI system error on slot <number>. Reseat PCI card
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PCI1354
Message A bus correctable error was detected on a component at slot
arg1
.
Arguments
arg1 =
number
Detailed
Description
System performance may be degraded.
Recommended
Response Action
Cycle input power, update component drivers, remove and re-install the device at the next
scheduled service time.
Category System Health
SubCategory PCI = PCI Device
Severity Severity 1 (Critical)