Solving Problems Described by LCD Status Messages
The code and text on the LCD can often specify a very precise fault condition that is easily corrected. For example, if the code E1418 CPU_1_Presence appears,
you know that a microprocessor is not installed in socket 1.
In contrast, you might be able to determine the problem if multiple related errors occur. For example, if you receive a series of messages indicating multiple
voltage faults, you might determine that the problem is a failing power supply.
Removing LCD Status Messages
For faults associated with sensors, such as temperature, voltage, fans, and so on, the LCD message is automatically removed when that sensor returns to a
normal state. For example, if temperature for a component goes out of range, the LCD displays the fault; when the temperature returns to the acceptable
range, the message is removed from the LCD. For other faults, you must take action to remove the message from the display:
l Clear the SEL You can perform this task remotely, but you will lose the event history for the system.
l Power cycle Turnoffthesystemanddisconnectitfromtheelectricaloutlet;waitapproximatelytenseconds,reconnectthepowercable,andrestart
the system.
Controller
E2017
Timer Fail
Timer refresh failure.
See Getting Help.
E2018
Prog Timer
Programmable interval timer error.
See Getting Help.
E2019
Parity Error
Parity error.
See Getting Help.
E201A
SIO Err
SIO failure.
See Getting Help.
E201B
Kybd
Controller
Keyboard controller failure.
See Getting Help.
E201C
SMI Init
System management interrupt (SMI) initialization failure.
See Getting Help.
E201D
Shutdown Test
BIOS shutdown test failure.
See Getting Help.
E201E
POST Mem Test
BIOS POST memory test failure.
See Troubleshooting System Memory. If the problem persists, see
Getting Help.
E201F
DRAC Config
Dell remote access controller (DRAC) configuration failure.
Check for specific error messages.
Ensure that DRAC cables and connectors are properly seated. If the
problem persists, see your DRAC documentation.
E2020
CPU Config
CPU configuration failure.
Check for specific error messages.
E2021
Memory
Population
Incorrect memory configuration. Memory population order
incorrect.
Check for specific error messages. See Troubleshooting System
Memory.
E2022
POST Fail
General failure after video.
Check for specific error messages.
E2110
MBE Crd #
DIMM ## & ##
One of the DIMMs in the set implicated by "## & ##" has
had a memory multi-bit error (MBE). If no memory card is
present, the "Crd #" string is left out of the message.
See Troubleshooting System Memory.
E2111
SBE Log
Disable Crd #
DIMM ##
The system BIOS has disabled memory single-bit error (SBE)
logging, and will not resume logging further SBEs until the
system is rebooted. "##" represents the DIMM implicated
by the BIOS. If no memory riser card is present, the "Crd #"
string is left out of the message.
See Troubleshooting System Memory.
E2112
Mem Spare Crd
# DIMM ##
The system BIOS has spared the memory because it has
determined that the memory had too many errors. "## &
##" represents the DIMM pair implicated by the BIOS. If no
memory card is present, the "Crd #" string is left out of the
message.
See Troubleshooting System Memory.
E2113
Mem Mirror
Crd # DIMM ##
& ##
The system BIOS has disabled memory mirroring because it
has determined that one half of the mirror has had too
many errors. "## & ##" represents the DIMM pair
implicated by the BIOS. If no memory card is present, the
"Crd #" string is left out of the message.
See Troubleshooting System Memory.
E2118
Fatal NB Mem
CRC
One of the connections in the FBD memory subsystem link
on the Northbound side has failed.
See Troubleshooting System Memory.
E2119
Fatal SB Mem
CRC
One of the connections in the FBD memory subsystem link
on the Southbound side has failed.
See Troubleshooting System Memory.
I1910
Intrusion
System cover has been removed.
Information only.
I1911
>3 ERRs Chk
Log
LCD overflow message.
A maximum of three error messages can display
sequentially on the LCD. The fourth message displays as
the standard overflow message.
Check the SEL for details on the events.
I1912
SEL Full
System Event Log is full of events, and is unable to log any
more events.
Clear the log by deleting event entries.
W1228
ROMB Batt <
24hr
Warns predictively that the RAID battery has less than 24
hours of charge left.
Replace RAID battery. See RAID Battery.
NOTE: For the full name of an abbreviation or acronym used in this table, see the Glossary.