Dell Chassis Management Controller Version 4.50 Guía de usuario

Busca en linea o descarga Guía de usuario para Servidores Dell Chassis Management Controller Version 4.50. Dell Chassis Management Controller Version 4.50 Command Line Reference Guide [pt] Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 428
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente

Indice de contenidos

Pagina 1 - 1.50.50 and CMC 4.5

RACADM Command Line Reference Guide for iDRAC7 1.50.50 and CMC 4.5

Pagina 3 - Contents

ff00::/8 :: U 256 0 0 ethlKernel IP routing tableDestinationGateway Genmask Flags MSS Window irtt Iface10.94.161.00.0.0.0 255.255.255.0U 0 0 0 bond00.

Pagina 4

• Displays the statistics for the integrated NIC.$ racadm nicstatistics NIC.Integrated.1-1Total Bytes Received:0Total Bytes Transmitted:

Pagina 5

Reply from 2011:de11:bdc:194::31: time<1ms Reply from 2011:de11:bdc:194::31: time<1ms Reply from 2011:de11:bdc:194::31: time<1ms Ping statist

Pagina 6

Active CMC Version = X08Standby CMC Version = N/ALast Firmware Update = Wed Nov 21 21:37:56 2007Hardware Version = 2Current IP Addr

Pagina 7

racresetDescription Resets iDRAC. The reset event is logged in the iDRAC log.Resets CMC. The reset event is logged in the hardware (SEL) and CMC (RAC)

Pagina 8

• To reset CMC.racadm racreset• To reset server 1.racadm racreset -m server-1• To reset servers 1 and 3.racadm racreset -m server-1 server-3racresetcf

Pagina 9

Example• Reset the configuration on iDRAC.racadm racresetcfgThe RAC configuration has initiated restoration to factory defaults.Wait up to a minute fo

Pagina 10

• To generate and view information about the inventory of virtual disks.raid get vdisksracadm raid get vdisks --refkey <controller FQDDs separated

Pagina 11 - Introduction

64k|128k|256k|512k|1M|2M|4M|8M|16M}]-pdkey:<comma separated PD FQDD> [-dcp {enabled|disabled|default}] [-name <VD name>] [-size <VD siz

Pagina 12 - RACADM Syntax Usage

– disabled — Does not allow the virtual disk to use the cache.– default — Uses the default cache policy. For SAS drives, use the disabled option and f

Pagina 13 - Remote RACADM

1IntroductionThis document provides information about the RACADM subcommands, supported RACADM interfaces, and property database groups and object def

Pagina 14 - RACADM Command Options

ReconstructRate = 30 % PatrolReadRate = 30 % PatrolReadMode = Automatic PatrolReadState

Pagina 15

This command displays all battery keys connected to the controllers.racadm raid get batteries --refkey RAID.Integrated.1-1Battery.Integrated.1:RAID.In

Pagina 16 - Supported RACADM Subcommands

FailurePredicted = NORemainingRatedWriteEndurance = Not ApplicableSecurityStatus = Not CapableBusProtocol

Pagina 17

ManufacturedYear = 2012SasAddress = 0x5000C5005952386DFormFactor = 2.5 InchRaidNominalMedi

Pagina 18

– This command deletes the specified virtual disk.racadm raid deletevd:Disk.Virtual.0:RAID.Integrated.1-1– This command encrypts the specified virtual

Pagina 19

• -u — User name to access the network share.• -p — Password to access the network share.• -l — Image location on the network share; use double quotat

Pagina 20 - Other Documents You May Need

rollbackDescription Allows you to roll back the firmware to an earlier version.Synopsisracadm rollback <FQDD>NOTE: To get the list of available

Pagina 21 - Contacting Dell

NOTE: The actionpowerstatus is not allowed with -a option.Output Displays an error message if the requested operation is not completed, or a success m

Pagina 22

NOTE: • For configuration of staged objects such as BIOS or NIC, commit and reboot job creation must be used to apply the pending values. For more inf

Pagina 23 - RACADM Subcommand Details

Output• Object value modified successfully• Unsuccessful message indicating reason for the same.Example• Configure the iDRAC using a file.$ racadm set

Pagina 24

– Reset, clear, and import the RAID configuration to the controller.• Manage the properties of the ISM modules using the objects in the iDRAC.ServiceM

Pagina 25

– 1 — to use existing groupNOTE: If —e is 0, then admin password is mandatory.• <groupName> — Name of the group for administrative purpose. You

Pagina 26

Example• racadm setassettag -m chassis 783839–33• racadm setassettag 783839–33The asset tag was changed successfully.setchassisnameDescription Sets th

Pagina 27

• Disable flex address for fabric iDRAC.racadm setflexaddr -f idrac 0setledDescription Sets the state (blinking or not blinking) of the LED on the spe

Pagina 28

setniccfgDescription Sets the iDRAC IP address. It displays an error message if the requested operation could not be performed. A success message is d

Pagina 29

NOTE: • -o, -k, -p: These options can be specified for chassis only• -6: Sets static IPv6 addresses(w/ -soption). Enables autoconfig for IPv6(w/-d opt

Pagina 30

– mmmmmm is the number of microseconds– s is a + (plus) sign or a − (minus) sign, which indicates the sign of the offset.– off is the offset in minute

Pagina 31

NOTE: The OMSA server agent must be present and running on the server to use the Display Hostname feature. If the agent is not running, the setting is

Pagina 32 - User Guide

Telnet/SSH/serial RACADM:racadm sshpkauth -i <2 to 16> -k <1 to 4> -t<key-text>ViewThe view mode allows the user to view a user-spec

Pagina 33

wilU2VLw/iRH1ZymUFnut8ggbPQgqV2L8bsUaMqb5PooIIvV6hy4isCNJU=1024-bit RSA, converted from OpenSSH by [email protected] ID 2:Key ID 3:Key ID

Pagina 34

– –1=Base64– –2=PKCS12The current release does not support this option.• -p — Pass phrase for decrypting the PKCS12 file uploaded.• -k — Filename of t

Pagina 35

Local RACADMracadm getconfig -g <groupname> [-o <objectname>][-i <indexnumber>]racadm <subcommand>Exampleracadm getconfig -g i

Pagina 36

State (S) TexasLocality (L)Round RockOrganization (O)Dell Inc.Organizational Unit (OU)Remote Access GroupCommon Name (CN)iDRAC7 Default certificateIss

Pagina 37

racadm sslcertview -t 1 -A00USTexasRound RockDell Inc.Remote Access GroupiDRAC7 default certificateUSTexasRound RockDell Inc.Remote Access GroupiDRAC7

Pagina 38

Input• -g — Generates a new CSR.• -s — Returns the status of a CSR generation process (generation in progress, active, or none).• -f — Specifies the f

Pagina 39

Example$ racadm sslresetcfgCertificate generated successfully and webserver restarted.NOTE: For more information about managing SSL certificates, see

Pagina 40

NOTE: • To run this subcommand, you require the Server Profile Export and Import license.• Backup operation is licensed but restore operation is not l

Pagina 41

NOTE: The -dom, -wom, or -dow option must be included in the command for the autoupdate schedule. The * value for the options must be included within

Pagina 42

– AutoBackup system to NFS share and encrypt the data.racadm systemconfig backup -f image.img -l 192.168.2.140:/share -u admin -p passwd -n encryptpas

Pagina 43

Input• -f <feature> — options are:– AD — Test AD using simple authentication– ADKRB — Test AD using Kerberos authentication– LDAP — Test Generic

Pagina 44

ExampleCommands for the cfgIpmiPet group:• Enable the alert.racadm config -g cfgIpmiPet -o cfgIpmiPetAlertEnable -i 1 • Set the destination email IP a

Pagina 45

traceroute6Description Traces the network path of routers as the packets traverse from the system to a destination IPv6 address.To run this subcommand

Pagina 46

VLanMode = DisabledWakeOnLan = Disabled• To display a single attribute for the specified group, run:racadm get device.<group name>.

Pagina 47

For update from repository .xml files are allowed.If a file name is not specified for repository update, then the Catalog.xml is taken as default.• -u

Pagina 48

• Upload the update file from a remote NFS share.racadm update -f <updatefile> -l 1.2.3.4:/share• Upload the update file from the local file sys

Pagina 49

usercertviewDescription Displays the user certificate or user CA certificate that exists on iDRAC.This subcommand is applicable only for iDRAC.Synopsi

Pagina 50

NOTE: • To run this subcommand, you must have the iDRAC7 Enterprise license.• After iDRAC restart, the status of the previous operation performed on t

Pagina 51

NOTE: – This feature is not supported in Local RACADM.– Creating vFlash partition from an image file on the CFS or NFS IPv6 enabled network share is n

Pagina 52

3iDRAC and CMC Property Database Group and Object DescriptionsThe iDRAC and CMC property database contains the configuration information for iDRAC and

Pagina 53

Subcommand iDRAC on Blade Servers iDRAC on Rack and Tower ServersCMCcfgRacSecurity No No YescfgRacVirtual Yes Yes NocfgServerInfo No Yes YescfgActiveD

Pagina 54

The following sections provide information about the objects in the idRACInfo group.idRacProductInfo (Read Only)DescriptionA text string that identifi

Pagina 55

iDRAC Type (Read Only)DescriptionIdentifies the remote access controller type.Legal ValuesProduct IDDefault For CMC: 9For 10G iDRAC: 8For 11G iDRAC6 o

Pagina 56

cfgNicIPv4Enable (Read or Write)DescriptionEnables or disables iDRAC or CMC IPv4 stack.Legal Values• 1 (TRUE)• 0 (FALSE)Default0cfgNicSelection (Read

Pagina 57

Using The Autocomplete FeatureUse the autocomplete feature to:• Display all the available RACADM commands in the alphabetical order on pressing the &l

Pagina 58

NOTE: For iDRAC Enterprise on Blade Servers, this object enables or disables the VLAN capabilities of iDRAC from CMC.Read only for iDRAC on Blade serv

Pagina 59

Default0For CMC, this property is used only if cfgNicUseDhcp is set to 1(true), or if both cfgIPv6Enable and cfgIPv6AutoConfig are set to 1(true).The

Pagina 60

NOTE: For IPv6, only the DHCPv6 address or static address is registered.Example:racadm getconfig -g cfgLanNetworkingcfgNicEnable=1cfgNicIPv4Enable=1cf

Pagina 61

cfgDNSServer2 (Read or Write)DescriptionRetrieves the IPv4 address for DNS server 2. This parameter is only valid if cfgDNSServersFromDHCP is set to 0

Pagina 62

cfgNicGateway (Read or Write)DescriptioniDRAC or CMC gateway IPv4 address.The gateway IPv4 address used for static assignment of the RAC IP address. T

Pagina 63

cfgNicStaticIPv4Enable (Read or Write)DescriptionEnables or disables the IPv4 stack.Legal Values• 0 — Disabled• 1 — EnabledDefault1 — EnabledNOTE: If

Pagina 64

cfgDNSStaticServersFromDHCP (Read or Write)DescriptionSpecifies the DNS server static IP addresses.Legal Values• DNS Addresses are configured on the D

Pagina 65

cfgRemoteHostsThis group provides properties that allow configuration of the SMTP server for email alerts.For CMC, this group enables/disables and con

Pagina 66

cfgRhostsNtpEnableDescription Enables or disables the use of the Network Time Protocol (NTP) for date and time synchronization.This object is applicab

Pagina 67

cfgRhostsSyslogEnable (Read or Write)DescriptionTo allow the RAC and SEL logs to be written to up to three remote syslog servers Enables or disables r

Pagina 68

setledsetniccfgsshpkauthsslcertviewsslcertdeletesslcsrgensslEncryptionStrengthsslkeyuploadsslresetcfgswinventorysystemconfigtestemailtesttraptestalert

Pagina 69

Default<blank>cfgRhostsSyslogPowerLoggingEnabledDescription To remote syslog servers, Enables or disables power consumption logging.This object

Pagina 70

NOTE: In the current CMC firmware version, the objects cfgUserAdminEnable and cfgUserAdminPrivilege are interrelated; changing the value of one proper

Pagina 71

Exampleracadm getconfig -g cfgUserAdmin -i 1# cfgUserAdminIndex=1cfgUserAdminEnable=1cfgUserAdminUserName=root# cfgUserAdminPassword=******** (Write-O

Pagina 72

Fabric A Administrator0x0000200Fabric B Administrator0x0000400Fabric C Administrator0x0000800ExamplesThe following table provides sample privilege bit

Pagina 73

cfgUserAdminPassword (Write Only)DescriptionThe password for this user. User passwords are encrypted and cannot be seen or displayed after the propert

Pagina 74

cfgEmailAlertThis group contains parameters to configure iDRAC or CMC email alerting capabilities. Up to four instances of this group are allowed.Use

Pagina 75

This object property is specific to CMC.Legal ValuesA string of up to 32 charactersDefault<blank>Exampleracadm getconfig -g cfgEmailAlert -i 2#

Pagina 76

An expired web server session logs out the current session.Legal Values60–10800Default1800cfgSsnMgtSshIdleTimeout (Read or Write)DescriptionDefines th

Pagina 77

• For iDRAC Enterprise on Blade Servers and CMC: 1800cfgSerialThis group contains configuration parameters for iDRAC or CMC services. One instance of

Pagina 78

For CMC:This key specifies the character that ends the serial text console connect (or racadm connect) command.NOTE: The CTRL key is represented by us

Pagina 79

Subcommand iDRAC on Blade Servers iDRAC on Rack and Tower Servers CMCTelnet/SSH/SerialLocal RACADMRemote RACADMTelnet/SSH/SerialLocal RACADMRemote RAC

Pagina 80 - Host name

cfgSerialConsoleColumnsDescriptionSpecifies the number of columns in the terminal window command line connected to the serial port. To take effect log

Pagina 81

cfgSerialHistorySize=8192cfgSerialTelnetEnable=0cfgSerialSshEnable=1cfgSerialTelnetEnable (Read or Write) DescriptionEnables or disables the Telnet co

Pagina 82

cfgTrapsThis group displays information for and configures delivery of SNMP traps for a specific user.This group is applicable only for CMC. Use this

Pagina 83

cfgRacTuningThis group is used to configure various iDRAC or CMC configuration properties, such as valid ports and security port restrictions.Use this

Pagina 84

cfgRacTuneCtrlEConfigDisableDescriptionTo configure iDRAC from the BIOS POST option-ROM, enables or disables the ability of the local user.This object

Pagina 85 - Blade Type

• cfgRacTuneIpRanbeMask bit-wise and with cfgRacTuneIpRangeAddrLegal ValuesAn IPv4 address formatted string, for example, 192.168.0.44.Default192.168.

Pagina 86

cfgRacTuneIpBlkPenaltyTime (Read or Write)DescriptionDefines the time span in seconds that session requests from an IP address with excessive failures

Pagina 87 - Install Date

NOTE: For CMC, the following port numbers are reserved and cannot be used: 21, 68, 69, 123, 161, 546, 801, 4096, 5988, 5989, 6900, 9000, 60106.Legal V

Pagina 88

Exampleracadm getconfig -g cfgRacTuning [-m server-<n>] -o<object name> <object value>cfgRacTuneRemoteRacadmEnable=1cfgRacTuneWebser

Pagina 89

NOTE: This object property is applicable only to iDRAC.Legal Values• 1 (TRUE — Enables)• 0 (FALSE— Disables)Default1cfgRacTuneLocalConfigDisable (Read

Pagina 90

Subcommand iDRAC on Blade Servers iDRAC on Rack and Tower Servers CMCTelnet/SSH/SerialLocal RACADMRemote RACADMTelnet/SSH/SerialLocal RACADMRemote RAC

Pagina 91

Default0cfgRacTunePluginType (Read or Write)Description To virtual console from browser, specifies the plug-in type.This object property is applicable

Pagina 92

• 1 = Attach• 2 = AutoAttachDefault0cfgVirtualBootOnce (Read or Write)DescriptionEnables or disables the Virtual Media Boot Once feature of iDRAC.If t

Pagina 93

For CMC, this group allows you to display and configure a server in the chassis.Use this object with the config or getconfig subcommands.To use this o

Pagina 94

cfgServerBIOS (Read Only)Description Displays the server's BIOS revision.This object is applicable only to CMC.Legal ValuesNoneDefaultNonecfgServ

Pagina 95

DefaultNonecfgServerPriority (Read/Write)Description Sets the priority level allotted to the server in the chassis for power budgeting purposes.This o

Pagina 96

DefaultNonecfgServerDNSIMCName (Read or Write)Description Displays the DNS domain name for the integrated Remote Access Controller (iDRAC).This object

Pagina 97

cfgServerBootOnce (Read or Write)Description Enables or disables the server start once feature.For CMC, this object is Write only.Legal Values• 1(True

Pagina 98

# cfgServerServiceTag=1S0M0G1cfgServerName=SLOT-01# cfgServerFW=1.40 (Build 12)# cfgServerBIOS=4.0.2# cfgServerBmcMacAddress=00:18:8B:FF:41:43# cfgSer

Pagina 99

This object is applicable only to CMC.Legal ValuesAny printable text string of up to 254 characters, with no white space.Default<blank>cfgADEnab

Pagina 100

This object is applicable only to iDRAC.Legal ValuesA string of up to 254 ASCII characters representing a valid IP address or a fully qualified domain

Pagina 101

Subcommand iDRAC on Blade Servers iDRAC on Rack and Tower Servers CMCTelnet/SSH/SerialLocal RACADMRemote RACADMTelnet/SSH/SerialLocal RACADMRemote RAC

Pagina 102

This object is applicable only to CMC.Legal Values• 1 (enabled)• 0 (disabled)Default0cfgADGlobalCatalogDescriptionTo obtain user names, specify the Gl

Pagina 103

This object is applicable only to iDRAC.Legal ValuesA string of up to 254 ASCII characters representing a valid IP address or a fully qualified domain

Pagina 104

cfgADGcSRVLookupEnable (Read or Write)DescriptionDetermines how the global catalog server is looked up. If using pre‑configured global catalog servers

Pagina 105

NOTE: You can specify multiple servers by separating each server with a comma. For example, example.com, sub1.example.comLegal ValuesString.• For iDRA

Pagina 106

For CMC: If enabled, the CMC performs DN matching, otherwise the CMC uses the user name provided at login for matching.Legal Values• 1(TRUE) — Use the

Pagina 107

cfgLDAPNetworkTimeoutDescription Configures the network timeout in seconds.This object is applicable only to CMC.Legal ValuesPositive integerDefault30

Pagina 108

For CMC, this group configures Generic LDAP Role group descriptions and defines the CMC privileges that LDAP-authenticated users are granted.Use this

Pagina 109

cfgLocationThis group defines objects that support physical location properties. Use this object with the config or getconfig subcommands.To use this

Pagina 110

To use this object property for CMC, you must have the Chassis Configuration Administrator privilege.NOTE: For CMC, you can configure a setting that d

Pagina 111

Configure iDRAC 0x00000002Configure Users 0x00000004Clear Logs 0x00000008Execute Server Control Commands 0x00000010Access Virtual Console 0x00000020Ac

Pagina 112

Notes, Cautions, and WarningsNOTE: A NOTE indicates important information that helps you make better use of your computer.CAUTION: A CAUTION indicates

Pagina 113

Subcommand iDRAC on Blade Servers iDRAC on Rack and Tower Servers CMCTelnet/SSH/SerialLocal RACADMRemote RACADMTelnet/SSH/SerialLocal RACADMRemote RAC

Pagina 114

cfgChassisEPPEnableDescription Enables the Extended Power Performance (EPP).Legal Values• 1 — Enabled• 0 — DisabledDefault0 — DisabledNOTE: For chassi

Pagina 115

cfgChassisPowerStatus (Read Only)DescriptionIndicates the power status of the chassis.Legal Values• 1 — (other)• 2 — (unknown)• 3 — (OK)• 4 — (noncrit

Pagina 116

Default43221 BTU/hrcfgChassisPowerCapFBTU (Read or Write)DescriptionIndicates the maximum power consumption limit (in BTU/hr) for the entire chassis.

Pagina 117

Default0 — (disabled)cfgChassisAllow110VACOperation (Read or Write)Description Enables or disables normal chassis power allocations when any PSU is co

Pagina 118

cfgChassisInRedundancyReserve (Read Only)DescriptionIndicates the amount of redundant power (in watts) in reserve that can be utilized in the event if

Pagina 119

cfgChassisPowerClearTimestamp (Read Only)DescriptionTime stamp when cfgChassisMinPower and cfgChassisMaxPowerCapacity were reset.Legal ValuesNoneDefau

Pagina 120

# cfgSystemEnergyConsumptionClear = ****(Write-Only)cfgChassisServerBasedPowerMgmtMode=0• racadm config -g cfgChassisPower ‑o cfgChassisPowerClear 1Cl

Pagina 121

• 4(Administrator)Default4cfgIpmiSolAccumulateInterval (Read or Write)DescriptionSpecifies the typical amount of time that iDRAC waits before transmit

Pagina 122

cfgIpmiLanAlertEnable (Read or Write)DescriptionEnables or disables global email alerting. This property overrides all individual email alerting enabl

Pagina 123

cfgIpmiPetIPv6AlertEnable (Read or Write)DescriptionEnables or disables the IPv6 alert destination for the trap.Legal Values• 1 (TRUE)• 0 (FALSE)Defau

Pagina 124

• For more information about IOM network settings, see the Dell PowerConnect M6220 Switch Important Information document and the Dell PowerConnect 622

Pagina 125 - Dell Chassis

cfgIpmiPefEnable (Read or Write)DescriptionEnables or disables a specific platform event filter.Legal Values• 1(TRUE)• 0(FALSE)Default1cfgIpmiPetThis

Pagina 126

cfgUserDomainIndex (Read Only)DescriptionRepresents a specific domain.Legal Values1–40DefaultThe index value.cfguserdomainname (Read Only)DescriptionS

Pagina 127

This object is applicable only for iDRAC.Legal ValuesNot applicableDefault<blank>cfgServerPowerCapEnable (Read or Write)DescriptionEnables or di

Pagina 128

cfgServerPowerConsumptionClear (Write Only)DescriptionClears the current recorded power statistics.This object is applicable only for iDRAC.Legal Valu

Pagina 129

cfgServerPowerLastDayAvg (Read Only)DescriptionDisplays the average power value during the last day.This object is applicable only for iDRAC.Legal Val

Pagina 130

This object is applicable only for iDRAC.Legal ValuesNot applicableDefaultMaximum power value during the last hour.cfgServerPowerLastHourMaxTime (Read

Pagina 131

cfgServerPowerLastDayMaxPower (Read Only)DescriptionDisplays the maximum power value during the last day.This object is applicable only for iDRAC.Lega

Pagina 132

• SS = SecondsDefaultTimestamp of the minimum power value during the last week.cfgServerPowerLastWeekMaxPower (Read Only)DescriptionDisplays the maxim

Pagina 133

cfgServerActualAmperageConsumption (Read Only)DescriptionDisplays the current power consumption.This object is applicable only for iDRAC.Legal ValuesN

Pagina 134

Time in the format: DD MM Date HH:MM:SS YYYYwhere,• DD = Day of the week• MM= Month• Date=Date• YYYY = Year• HH = hour• MM=Minutes• SS = SecondsDefaul

Pagina 136

DefaultNonecfgKVMFrontPanelEnableDescriptionEnables or disables front panel access on the iKVM.Legal Values• 1 (enable)• 0 (disable)DefaultNoneExample

Pagina 137

Examplesracadm getconfig -g cfgAlerting -o cfgAlertingSourceEmailNameracadm config -g cfgAlerting -o cfgAlertingSourceEmailName [email protected] va

Pagina 138

cfgServerPowerSupplyMaxOutputPower (Read Only)DescriptionDisplays the AC output rated power in Watts.Legal ValuesA string of up to 32 characters.Defau

Pagina 139

The following sections provide information about the objects in the cfgIPv6LanNetworking group.cfgIPv6Enable (Read or Write)DescriptionEnables or disa

Pagina 140

cfgIPv6AutoConfig (Read or Write)DescriptionEnables or disables the IPv6 Auto Configuration option.NOTE: If this value is set to0, the CMC disables au

Pagina 141

Default:cfgIPv6Address5 (Read Only)DescriptionThe iDRAC IPv6 fifth address.This object is applicable only for iDRAC.Legal ValuesString representing a

Pagina 142

Default:cfgIPv6Address11 (Read Only)DescriptionThe iDRAC IPv6 eleventh address.This object is applicable only for iDRAC.Legal ValuesString representin

Pagina 143

NOTE: This property is used only if cfgIPv6AutoConfig is set to 1(true).Legal Values1 (TRUE)0 (FALSE)DefaultFor iDRAC:0 For CMC: 1cfgIPv6DNSServer1 (R

Pagina 144

cfgIpv6StaticLanNetworkingThis group is used to configure the IPv6 Static over LAN networking capabilities. This group is applicable only for iDRAC.cf

Pagina 145 - Object Descriptions

NOTE: If this object is modified, then the object cfgIPv6Autoconfig is also modified.cfgIPv6StaticDNSServersFromDHCP6 (Read or Write)DescriptionSpecif

Pagina 146

2RACADM Subcommand DetailsThis section provides detailed description of the RACADM subcommands including the syntax and valid entries.Guidelines to Qu

Pagina 147

cfgNicCurrentGatewayDisplays the static gateway for the CMC IP address.DescriptionDisplays the static gateway for the CMC IP address.Legal ValuesDefau

Pagina 148

cfgDNSCurrentServer2DescriptionDisplays the IP address for DNS server 2.Legal ValuesDefaultcfgDNSCurrentDomainNameDescriptionDisplays the DNS domain n

Pagina 149

cfgCurrentIPv6AutoConfigWasUsedDescriptionIndicates whether auto configuration is used to obtain IPv6 settings, including stateless IPv6 addresses and

Pagina 150

cfgCurrentIPv6DNSServer2DescriptionDisplays the IPv6 address for DNS server 2.Legal ValuesNoneDefaultNoneExampleracadm getconfig -g cfgCurrentIPv6LanN

Pagina 151

cfgIpmiSerialChanPrivLimit (Read or Write)DescriptionSpecifies the maximum privilege level allowed on the IPMI serial channel.Legal Values• 2 (User)•

Pagina 152

Default1cfgIpmiSerialHandshakeControl (Read or Write)DescriptionEnables or disables the IPMI terminal mode handshake control.Legal Values• 0(FALSE)• 1

Pagina 153

cfgSmartCardLogonEnable (Read or Write)DescriptionTo iDRAC using a smart card, enable or disable with Remote RACADM support for access.NOTE: Enabling

Pagina 154

• 1 = Auto Negotiation is EnabledDefault1Exampleracadm getconfig -g cfgNetTuningcfgNetTuningNicSpeed=100cfgNetTuningNicFullDuplex=1cfgNetTuningNicMtu=

Pagina 155

cfgSensorRedundancyIndex (Read Only)DescriptionSpecifies index for the sensor redundancy group being read. Only power supply redundancy is supported.L

Pagina 156

cfgVFlashSDThis group is used to configure the properties for the Virtual Flash SD card. This group is applicable only for iDRAC.NOTE: If the vFlash c

Pagina 157

For using single quotation marks:• No character escaping is necessary.• A single quotation mark is not used even with a back slash escaped.NOTE: An em

Pagina 158

cfgVFlashSDAvailableSize (Read Only)DescriptionDisplays the available memory (in MB) on the vFlash SD card that can be used to create new partitions.L

Pagina 159

cfgVFlashPartitionSize (Read Only)Description Displays the size of the partition.Legal Values 1 MB to 4 GBDefaultNonecfgVFlashPartitionEmulationType (

Pagina 160

cfgVFlashPartitionAttachState (Read or Write)DescriptionView or modify the partition to attached or detached.NOTE: Detaching the vFlashPartition by se

Pagina 161

cfgRacSecCsrOrganizationName (Read or Write)DescriptionSpecifies the CSR Organization Name (O).Legal ValuesA string of up to 254 characters.Default<

Pagina 162

cfgRacSecOrganizationUnit=cfgRacSecLocalityName=cfgRacSecStateName=cfgRacSecCountryCode=cfgRacSecEmailAddr=cfgRacSecCsrKeySize (Read or Write)Descript

Pagina 163

4Database Objects With Get and Set CommandsThis chapter provides the database groups and objects that must be used with the get or set subcommands. Th

Pagina 164

System.ChassisInfo.Name (Read)Description Provides the name of the chassis. For example: CMC-nobel01.Legal Values String of up to 62 ASCII charactersD

Pagina 165

System.LCD.CurrentDisplay (Read Only)DescriptionThe string currently displayed on the LCD.Legal ValuesNoneWrite PrivilegeConfigure iDRACLicense Requir

Pagina 166

System.Location.DeviceSize (Read Only)DescriptionIndicates server chassis size.Legal ValuesValues: 1–255Default ValueDepends on the server form factor

Pagina 167

System.Location.Chassis.Name (Read Only)DescriptionIndicates the chassis name.Legal ValuesString of up to 128 ASCII charactersWrite PrivilegeConfigure

Pagina 168

getkvminfo -- display the KVM module information getled -- display the LED settings on a module getmacaddress -- get MAC/WWN addresse

Pagina 169

Default ValueAverage power value during the last day.Write PrivilegeConfigure iDRACLicense RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNoneSy

Pagina 170

Write PrivilegeConfigure iDRACLicense RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNoneSystem.Power.Cap.ActivePolicy.Watts (Read Only)Descript

Pagina 171

System.Power.Cap.MaxThreshold (Read Only)DescriptionBecause it is based on the current component inventory, it has maximum server power capacity.Legal

Pagina 172

• A/C Input Redundant — In this mode, the system is functional even if one PSU input circuit stops functioning, provided the PSUs are connected to dif

Pagina 173

System.Power.EnergyConsumption.Clear (Read or Write)DescriptionClears the cumulative power consumption timestamps.Legal Values1Write PrivilegeConfigur

Pagina 174

• 5 — PSU1 and PSU3• 10 — PSU2 and PSU4Write Privilege Configure iDRACLicense RequirediDRAC7 Express or iDRAC7 EnterpriseDependency NoneSystem.Power.M

Pagina 175

System.Power.Max.LastDay (Read Only)DescriptionDisplays the maximum power value during the last day.Legal ValuesValues: 1–65535Default ValueMaximum po

Pagina 176

Dependency NoneSystem.Power.Max.LastWeek (Read Only)DescriptionDisplays the maximum power value during the last week.Legal ValuesValues: 1–65535Defaul

Pagina 177

License RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNoneSystem.Power.Max.PowerClear (Read Only)DescriptionClears the Maximum Power Consumptio

Pagina 178

License RequirediDRAC7 Express or iDRAC7 EnterpriseDependency NoneSystem.Power.Min.LastHour.Timestamp (Read Only)Description Indicates the timestamp o

Pagina 179

-4 : show CMC IPv4 information-6 : show CMC IPv6 informationhelp and help <subcommand>DescriptionLists all the subcommands available for use wit

Pagina 180

• 1 — EnabledDefault Value• 0 — For platforms that do not support PCIe cards.• 500 W — For platforms that support PCIe cards.Write PrivilegeConfigure

Pagina 181

Default Value0 — not applicableSystem.Power.RedundantState (Read Only)DescriptionRetrieves the redundancy state for the chassis.Legal Values• 0 — None

Pagina 182

System.Power.Supply.[i].MaxOutputPower (Read Only)DescriptionDisplays the DC output rated power in Watts.Legal ValuesInteger > 0Default 0System.Pow

Pagina 183

System.ServerOS.HostName (Read or Write)DescriptionDisplays the host name of the managed server.Legal Values String of up to 256 ASCII charactersWrite

Pagina 184

• 255 — NoneDefault value 255 — NoneLicense RequirediDRAC7 ExpressDependency NoneSystem.ThermalSettings.BaseAlgorithm (Read or Write)Description Spec

Pagina 185

• 1 — EnabledDefault Value 0 — DisabledWrite Privilege Server ControlLicense RequirediDRAC7 EnterpriseDependency NoneLifecycleController.LCAttributes.

Pagina 186

License RequirediDRAC7 Express or iDRAC7 EnterpriseDependency NoneLifecycleController.LCAttributes.LifecycleControllerState (Read or Write)Description

Pagina 187

iDRAC.ActiveDirectoryTo manage the configuration of the iDRAC Active Directory features, use the objects in this group.iDRAC.ActiveDirectory.AuthTimeo

Pagina 188

iDRAC.ActiveDirectory.DCLookupDomainName (Read or Write)Description The configured search domain is used when DCLookupByUserDomain is disabled.Legal V

Pagina 189

Write Privilege Configure iDRACLicense RequirediDRAC7 EnterpriseDependencyNoneiDRAC.ActiveDirectory.DomainController3 (Read or Write)Description FQDN

Pagina 190

IP Address HW Type Flags HW Address Mask Device192.168.1.1 0x1 0x2 00:00:0C:07:AC:0F* eth0autoupdateschedulerDescription You can automatically update

Pagina 191

• IPv6.DNS2iDRAC.ActiveDirectory.GCRootDomain (Read or Write)DescriptionThe names of the Active Directory root domain used for DNS look up.Legal Value

Pagina 192

iDRAC.ActiveDirectory.RacDomain (Read or Write)DescriptionActive Directory Domain in which iDRAC resides.Legal Values String of up to 254 ASCII charac

Pagina 193

License RequirediDRAC7 EnterpriseDependencyCannot be enabled unless SmartCard Logon Enable is disabled.iDRAC.ADGroupTo manage the configuration of AD

Pagina 194

iDRAC.AutoOSLock.AutoOSLockState (Read or Write)Description Enable or Disable OS Auto lock feature.Legal Values • 0 — Disabled• 1 — EnabledDefault Val

Pagina 195

Default Value 0 — DisabledWrite Privilege Configure iDRACLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependencyNoneiDRAC.InfoTo manage informa

Pagina 196

iDRAC.Info.Product (Read Only)Description String identifying the Product.Legal ValuesString of up to 63 ASCII charactersWrite Privilege Configure iDRA

Pagina 197

Write Privilege Configure iDRACLicense RequirediDRAC7 Express or iDRAC7 EnterpriseDependency NoneiDRAC.IPBlockingTo configure IP address blocking fe

Pagina 198

iDRAC.IPBlocking.PenaltyTime (Read or Write)DescriptionDefines the time span in seconds that session requests from an IP address with excessive failur

Pagina 199

Write PrivilegeConfigure iDRACLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependencyNoneiDRAC.IPMILanTo configure IPMI over LAN of the system,

Pagina 200

DependencyNoneiDRAC.IPMILan.EncryptionKey (Read or Write)Description Enables or disables the IPMI over LAN interface.Legal ValuesString of up to 18 AS

Pagina 201

• -pp — Specifies the FTP proxy password.• -po — Specifies the FTP proxy port.• -pt — Specifies the FTP proxy type.• -time — Specifies the time to sch

Pagina 202

License Required iDRAC7 Express or iDRAC7 EnterpriseDependencyNoneiDRAC.IPMISerial.ChanPrivLimit (Read or Write)Description Specifies the maximum priv

Pagina 203

iDRAC.IPMISerial.EchoControl (Read or Write)DescriptionEnables or disables echo control on the IPMI serial interface.Legal Values • 0 — Disabled• 1 —

Pagina 204

• 2 — NullDefault Value 2 — NullWrite PrivilegeConfigure iDRACLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependencyNoneiDRAC.IPMISerial.LineE

Pagina 205

iDRAC.IPMISOL.AccumulateInterval (Read or Write)Description Specifies the typical amount of time that iDRAC waits before transmitting a partial SOL ch

Pagina 206

• 4—AdministratorDefault Value 4—AdministratorWrite Privilege Configure iDRACLicense RequirediDRAC7 Express or iDRAC7 EnterpriseDependency NoneiDRAC.I

Pagina 207 - 1-based 5ms

License RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyCannot be enabled unless IPv4.Enable is enabled.iDRAC.IPv4.DNS1 (Read or Write)Descriptio

Pagina 208

iDRAC.IPv4.Enable (Read or Write)DescriptionEnables or disables the iDRAC IPv4 stack.Legal Values• 0 — Disabled• 1 — EnabledDefault Value1 — EnabledWr

Pagina 209

iDRAC.IPv4Static.Address (Read or Write)DescriptioniDRAC static IPv4 address. This address can be configured even when DHCP is enabled.Legal ValuesVal

Pagina 210

DependencyNoneiDRAC.IPv4Static.Netmask (Read or Write)DescriptioniDRAC static IPv4 subnet mask. This address can be configured even when DHCP is enabl

Pagina 211

License RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNoneiDRAC.IPv6.Address 4 (Read Only)Description iDRAC IPv6 fourth address.Legal Values Va

Pagina 212

time = 14:30dayofmonth =1repeat = 5applyreboot = 1idracuser = racuser– To clear and display AutoUpdateScheduler parameter:racadm autoupd

Pagina 213

iDRAC.IPv6.Address 8 (Read Only)Description iDRAC IPv6 eighth address.Legal Values Valid IPv6 AddressWrite Privilege Configure iDRACLicense RequirediD

Pagina 214

iDRAC.IPv6.Address12 (Read Only)Description iDRAC IPv6 twelfth address.Legal ValuesValid IPv6 AddressWrite Privilege Configure iDRACLicense Required i

Pagina 215

iDRAC.IPv6.AutoConfig (Read or Write)DescriptionEnables or disables the iDRAC IPv6 auto configuration option.Legal Values• 0 — Disabled• 1 — EnabledDe

Pagina 216

License RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyCannot be Enabled unless IPv6.AutoConfig is enabled.iDRAC.IPv6.Enable (Read or Write)Desc

Pagina 217

License RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNoneiDRAC.IPv6StaticTo manage the IPv6 static configuration properties of iDRAC, use the

Pagina 218

Default Value0 — DisabledWrite PrivilegeConfigure iDRACLicense RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNoneiDRAC.IPv6Static.Gateway (Read

Pagina 219

iDRAC.LDAPTo configure properties for LDAP settings, use the objects in this group.iDRAC.LDAP.BaseDN (Read or Write)DescriptionThe Domain Name of the

Pagina 220

License RequirediDRAC7 EnterpriseDependencyNoneiDRAC.LDAP.Enable (Read or Write)DescriptionTurns LDAP service on or off.Legal Values• 0 — Disabled• 1

Pagina 221

Write PrivilegeConfigure iDRACLicense RequirediDRAC7 EnterpriseDependencyNoneiDRAC.LDAP.SearchFilter (Read or Write)DescriptionA valid LDAP search fil

Pagina 222

iDRAC.LDAPRoleGroup.DN (Read or Write)DescriptionThe Domain Name of this group.Legal ValuesString of up to 1024 ASCII charactersWrite PrivilegeConfigu

Pagina 223

Contents1 Introduction...

Pagina 224

chassisactionDescription Executes a power action on the chassis, iKVM or a server.This subcommand is applicable only for CMC.To use this subcommand, y

Pagina 225

• 1 — EnabledDefault Value0 — DisabledWrite PrivilegeConfigure iDRACLicense RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNoneiDRAC.LoggingiDRA

Pagina 226

NOTE: Always configures the DHCP.Default Values 0 — DisabledWrite Privilege Configure iDRACLicense RequirediDRAC7 EnterpriseDependency NoneiDRAC.NIC.

Pagina 227

License RequirediDRAC7 Express (for Blades) or iDRAC7 EnterpriseDependencyNoneiDRAC.NIC.DNSDomainFromDHCP (Read or Write)DescriptionSpecifies that the

Pagina 228

iDRAC.NIC.DNSRacName (Read or Write)Description The iDRAC name.Legal ValuesString of up to 63 ASCII charactersWrite Privilege Configure iDRACLicense R

Pagina 229

Write Privilege Configure iDRACLicense RequirediDRAC7 Express or iDRAC7 EnterpriseDependency NoneiDRAC.NIC.Failover (Read or Write)DescriptionEnables

Pagina 230

iDRAC.NIC.Selection (Read or Write)Description Specifies the current mode of operation for the iDRAC network interface controller.Legal Values • 1 — D

Pagina 231

iDRAC.NIC.VLanEnable (Read Only)Description Enables or disables the VLAN capabilities of the iDRAC.NOTE: This object is applicable only to iDRAC on Ra

Pagina 232

iDRAC.NICStatic.DNSDomainFromDHCP (Read or Write)Description Specifies that the iDRAC DNS domain name must be assigned from the network DHCP server.Le

Pagina 233

DependencyNoneiDRAC.NTPConfigGroup.NTP3 (Read or Write)DescriptionConfigure NTP Server 3 Address.Legal ValuesString of up to 254 ASCII characters.Writ

Pagina 234

iDRAC.OS-BMC.AdminState (Read or Write)Description On iDRAC pass through, enable or disable administrative state of OS.Legal Values • 0 — Disabled• 1

Pagina 235

clearpendingDescription Deletes the pending values of all the attributes (objects) in the device (NIC, BIOS, and Storage).This command is applicable o

Pagina 236

iDRAC.Racadm.Enable (Read or Write)Description Enables or disables Remote RACADM interface.Legal Values • 0 — Disabled• 1 — EnabledWrite Privilege Con

Pagina 237

Write PrivilegeConfigure iDRACLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependencyNoneiDRAC.RFSTo configure Remote file share access to iDRA

Pagina 238

iDRAC.Security.CsrCommonName (Read or Write)DescriptionSpecifies the CSR Common Name (CN) that must be an IP as given in the certificate.Legal ValuesS

Pagina 239

iDRAC.Security.CsrLocalityName (Read or Write)Description Specifies the CSR Locality (L).Legal Values String of up to 254 ASCII charactersWrite Privil

Pagina 240

NOTE: This is supported only for rack and tower systems.iDRAC.Serial.BaudRate (Read or Write)Description Sets the Baud rate on the iDRAC serial port.L

Pagina 241

iDRAC.Serial.HistorySize (Read or Write)Description Specifies the maximum size of the serial history buffer.Legal Values Integral values from 0 to 819

Pagina 242

iDRAC.SerialRedirection.Enable (Read or Write)DescriptionEnables or disables the console for COM2 port redirection.Legal Values• 0 — Disabled• 1 — Ena

Pagina 243

iDRAC.serverboot.FirstBootDeviceDescription Configures the first boot device.Legal Values• Normal• PXE• HDD (Hard Disk Drive)• CD-DVD (Local CD/DVD)•

Pagina 244

• 1 — EnabledDefault Value 1 — EnabledWrite Privilege Configure iDRACLicense RequirediDRAC7 Express or iDRAC7 EnterpriseDependency NoneiDRAC.Service

Pagina 245 - System.ChassisInfo

iDRAC.ServiceModule.WatchdogRecoveryAction (Read and Write)Description Configures recovery action on watchdog alert.Legal Values• 0 — None• 1 — Reboot

Pagina 246 - System.LCD

clrraclogDescription Deletes the CMC log.This subcommand is applicable only for CMC.Synopsisracadm clrraclogInputracadm clrraclogclrselDescription Rem

Pagina 247 - System.Location

iDRAC.SmartCard.SmartCardCRLEnable (Read or Write)Description Enables or disables the Certificate Revocation List (CRL).Legal Values • 0 — Disabled• 1

Pagina 248

iDRAC.SNMP.AgentEnable (Read or Write)Description Enables or disables the SNMP Agent on the iDRAC.Legal Values • 0 — Disabled• 1 — EnabledDefault Valu

Pagina 249 - System.Power

License Required iDRAC7 Express or iDRAC7 EnterpriseDependencyNoneiDRAC.SNMP.TrapFormat (Read or Write)Description Specifies the SNMP format.Legal Val

Pagina 250

License RequiredNoneDependencyNoneiDRAC.SSHThe objects in this group provide configuration parameters for the SSH interface to iDRAC.iDRAC.SSH.Enable

Pagina 251

iDRAC.SysLogThe objects in this group provide the properties for configuration of the SMTP server.iDRAC.SysLog.Port (Read or Write)DescriptionRemote s

Pagina 252 - System.Power.Redundancypolicy

iDRAC.SysLog.Server1 (Read or Write)Description Name of remote syslog server 1.Legal Values String of up to 63 ACSII charactersWrite Privilege Configu

Pagina 253

iDRAC.TelnetThe objects in this group provide configuration parameters for the Telnet interface to iDRAC.iDRAC.Telnet.Enable (Read or Write)Descriptio

Pagina 254

iDRAC.Time.Timezone (Read or Write)Description Configure the time zone.Legal Values Valid time zone string of up to 32 ASCII characters For example: U

Pagina 255

iDRAC.Update.FwUpdatePath (Read or Write)DescriptionSpecifies TFTP path where iDRAC firmware image resides on TFTP server. Path is relative to TFTP ro

Pagina 256

iDRAC.Users.Enable (Read or Write)DescriptionEnables or disables an individual user.Legal Values • 0 — Disabled• 1 — EnabledDefault Value0 — Disabled.

Pagina 257

For CMC only:racadm config -g <group> -o <object> <value> [-m <module>]InputNOTE: The -f and -p options are not supported for

Pagina 258

DependencyBoth username and password must be configured prior to setting this object.iDRAC.Users.Password (Write Only)DescriptionConfiguring the iDRAC

Pagina 259

Default Value0 — DisabledWrite Privilege Configure iDRAC and Configure UserLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependencyNoneiDRAC.Use

Pagina 260

iDRAC.vflashpartitionThe objects in this group manage vFlash SD partitions on iDRAC.This group supports the following objects. Up to 16 partitions are

Pagina 261 - System.Power.Supply

iDRAC.vflashpartition.FormatType (Read Only)Description Specifies the file system format type of the vFlash SD partition.Legal Values• FAT16• FAT32• E

Pagina 262 - System.ServerOS

iDRAC.vflashsd.AvailableSize (Read Only)Description Displays the available memory (in MB) on the vFlash SD card that is used to create new partitions.

Pagina 263 - System.ThermalSettings

• 1 — InitializedDefault value NoneWrite Privilege Login and configure iDRACLicense RequirediDRAC7 EnterpriseDependency vFlash SD card must be enabl

Pagina 264

iDRAC.VirtualConsoleThe objects in this group enable you to manage virtual console configuration parameters of iDRAC.iDRAC.VirtualConsole.AccessPrivil

Pagina 265

iDRAC.VirtualConsole.LocalVideo (Read or Write)DescriptionEnables or disables the local server video.Legal Values• 0 — Disabled• 1 — EnabledDefault Va

Pagina 266

Write Privilege Configure iDRACLicense Required iDRAC7 Express (For Blades) or iDRAC7 EnterpriseDependencyNoneiDRAC.VirtualConsole.Timeout (Read or Wr

Pagina 267

License RequirediDRAC7 Express (For Blades) or iDRAC7 EnterpriseDependencyNoneiDRAC.VirtualMedia.FloppyEmulation (Read or Write)Description Enables of

Pagina 268

For CMC only:• To configure the single property of a group:racadm config -g cfgSerial -o cfgSerialBaudRate• To modify a user password:racadm config -g

Pagina 269

Dependency NoneiDRAC.VNCServer.Password (Read or Write)Description Password for logging into VNC session.Legal Values String of up to 8 charactersDef

Pagina 270

Default Value1 — EnabledWrite Privilege Configure iDRACLicense RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNoneiDRAC.WebServer.HttpPort (Read

Pagina 271

iDRAC.WebServer.LowerEncryptionBitLength (Read or Write)Description Lower Encryption Bit Length.Legal Values• 0 — Disabled (Auto Negotiate)• 1 — Enabl

Pagina 272

Write PrivilegeServer ControlLicense RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNoneBIOS.BiosBootSettings.BootSeqRetry (Read or Write)Descri

Pagina 273

• EnablediScsi• DisabledWrite PrivilegeServer ControlLicense RequirediDRAC7 Express or iDRAC7 EnterpriseDependency NoneBIOS.IntegratedDevices.EmbNic1N

Pagina 274

License RequirediDRAC7 Express or iDRAC7 EnterpriseDependency NoneBIOS.IntegratedDevices.EmbNic3Nic4 (Read or Write)DescriptionEnables or disables the

Pagina 275

BIOS.IntegratedDevices.IntegratedNetwork1 (Read or Write)DescriptionEnables or disables the Integrated Network Card 1.Legal Values• Enabled• Disabled

Pagina 276

DependencyNoneBIOS.IntegratedDevices.InternalSdCard (Read or Write)DescriptionEnables or disables the internal SD Card port.Legal Values• On• OffWrite

Pagina 277

License RequirediDRAC7 Express or iDRAC7 EnterpriseDependency NoneBIOS.IntegratedDevices.InternalUsb2 (Read or Write)DescriptionEnables or disables th

Pagina 278

License RequirediDRAC7 Express or iDRAC7 EnterpriseDependency NoneBIOS.IntegratedDevices.SriovGlobalEnable (Read or Write)DescriptionEnables or disabl

Pagina 279

For more information about clearing the coredump, see the coredumpdelete subcommand.Synopsisracadm coredumpInputNoneOutputNoneExample• racadm coredump

Pagina 280

BIOS.MemSettings.MemOpMode (Read Only)DescriptionCurrent memory operating mode.Legal Values• OptimizerMode• SpareMode• MirrorMode• AdvEccMode• SpareWi

Pagina 281

License RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNoneBIOS.MemSettings.NodeInterleave (Read or Write)DescriptionIf the system is configured

Pagina 282

BIOS.MemSettings.RedundantMemInUse (Read Only)DescriptionDisplay the current redundant memory setting in BIOS.Legal Values• NotInUse• InUseWrite Privi

Pagina 283

BIOS.MemSettings.SysMemSpeed (Read Only)DescriptionIndicates the current clock frequency of the main memory.Legal ValuesNoneWrite PrivilegeServer Cont

Pagina 284

BIOS.MiscSettings.AssetTag (Read or Write)DescriptionDisplays the current asset tag and the asset tag can be modified.Legal ValuesNoneWrite PrivilegeS

Pagina 285

BIOS.MiscSettings.ReportKbdErr (Read or Write)DescriptionEnables or disables the keyboard-related error messages to be reported at system startup.Lega

Pagina 286

Write PrivilegeServer ControlLicense RequirediDRAC7 Express or iDRAC7 EnterpriseDependency Read Only if OneTimeBootMode is not set to OneTimeBootSeq.B

Pagina 287

Write PrivilegeServer ControlLicense RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNoneBIOS.ProcSettings.DataReuse (Read or Write)DescriptionEn

Pagina 288

Write PrivilegeServer ControlLicense RequirediDRAC7 Express or iDRAC7 EnterpriseDependency NoneBIOS.ProcSettings.LogicalProc (Read or Write)Descriptio

Pagina 289

BIOS.ProcSettings.Proc1L3Cache (Read Only)DescriptionAmount of memory in the corresponding processor cache.Legal ValuesNoneWrite PrivilegeServer Contr

Pagina 290

where <prefixlen> must be a number between 0 and 128.racadm deploy-m server -<n> -u root -p <password> -d [-6]racadm deploy -m swi

Pagina 291

Write PrivilegeServer ControlLicense RequirediDRAC7 Express or iDRAC7 EnterpriseDependency NoneBIOS.ProcSettings.Proc2L3Cache (Read Only)DescriptionAm

Pagina 292

BIOS.ProcSettings.Proc3L2Cache (Read Only)DescriptionAmount of memory in the corresponding processor cache.Legal ValuesNoneWrite PrivilegeServer Contr

Pagina 293

License RequirediDRAC7 Express or iDRAC7 EnterpriseDependency NoneBIOS.ProcSettings.Proc4L2Cache (Read Only)DescriptionAmount of memory in the corresp

Pagina 294

BIOS.ProcSettings.ProcAdjCacheLine (Read or Write)DescriptionEnables or disables the system optimization for applications that require high utilizatio

Pagina 295

BIOS.ProcSettings.ProcCoreSpeed (Read Only)DescriptionClock speed of the processor.Legal ValuesNoneWrite PrivilegeServer ControlLicense RequirediDRAC7

Pagina 296

BIOS.ProcSettings.ProcHtAssist (Read or Write)DescriptionWhen enabled it provides filtering of broadcast probes to improve HyperTransport I/O Link ban

Pagina 297

License RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNoneBIOS.ProcSettings.ProcVirtualization (Read or Write)DescriptionWhen enabled, the addi

Pagina 298

BIOS.ProcSettings.RtidSetting (Read or Write)DescriptionAllocates more RTIDs to the remote socket increasing cache performance between the sockets.Leg

Pagina 299

Write PrivilegeServer ControlLicense RequirediDRAC7 Express or iDRAC7 EnterpriseDependency NoneBIOS.SataSettings.eSataPort1DriveType (Read Only)Descri

Pagina 300

BIOS.SataSettings.SataPortADriveType (Read Only)DescriptionIndicates type of device attached to this SATA port.Legal ValuesNoneWrite PrivilegeServer C

Pagina 301

Example• Set root password, configure static IPV4 address, set first boot device to HDD, and enable boot once for server-1.racadm deploy -m server-1 -

Pagina 302

BIOS.SataSettings.SataPortBDriveType (Read Only)DescriptionIndicates type of device attached to this SATA port.Legal ValuesNoneWrite PrivilegeServer C

Pagina 303

BIOS.SataSettings.SataPortCDriveType (Read Only)DescriptionIndicates type of device attached to this SATA port.Legal ValuesNoneWrite PrivilegeServer C

Pagina 304

Write PrivilegeServer ControlLicense RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNoneBIOS.SataSettings.SataPortDDriveType (Read Only)Descript

Pagina 305

BIOS.SataSettings.SataPortEDriveType (Read Only)DescriptionIndicates type of device attached to this SATA port.Legal ValuesNoneWrite PrivilegeServer C

Pagina 306

DependencyNoneBIOS.SataSettings.SataPortFModel (Read Only)DescriptionDisplays the drive model of the selected device.Legal ValuesNoneWrite PrivilegeSe

Pagina 307

Write PrivilegeServer ControlLicense RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNoneBIOS.SataSettings.SataPortH (Read or Write)DescriptionSe

Pagina 308

BIOS.SerialCommSettingsTo manage the serial port settings, use the objects in the group.BIOS.SerialCommSettings.ConTermType (Read or Write)Description

Pagina 309

BIOS.SerialCommSettings.RedirAfterBoot (Read or Write)DescriptionEnables or disables the BIOS console redirection when the operating system is loaded.

Pagina 310

BIOS.SlotDisablement.Slot1 (Read or Write)DescriptionControl the configuration of the card installed in slot1.Legal Values• Enabled• Disabled• BootDri

Pagina 311

Write PrivilegeServer ControlLicense RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNoneBIOS.SlotDisablement.Slot5 (Read or Write)DescriptionCon

Pagina 312

• -p <password> — Specifies the password of the remote share to import the file.• -r <reboot type> — Specifies the reboot type. The type c

Pagina 313

BIOS.SysInformationTo view information about system configuration, use the objects in this group.BIOS.SysInformation.SysMfrContactInfo (Read Only)Desc

Pagina 314

BIOS.SysInformation.SystemModelName (Read Only)DescriptionProvides the product name of the system.Legal ValuesNoneWrite PrivilegeServer ControlLicense

Pagina 315

• MaxReliabilityWrite PrivilegeServer ControlLicense RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyRead Only if SysProfileSettings.SysProfile i

Pagina 316

BIOS.SysProfileSettings.MemVolt (Read/Write)DescriptionSets the DIMM voltage selection.Legal Values• AutoVolt• Volt135V• Volt15VLicense RequirediDRAC7

Pagina 317

BIOS.SysProfileSettings.ProcCStates (Read or Write)DescriptionEnables or disables the processor C-States.Legal Values• Enabled• DisabledWrite Privileg

Pagina 318

• Custom• DenseCfgOptimizedWrite PrivilegeServer ControlLicense RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNoneBIOS.SysSecurityTo manage the

Pagina 319

Write PrivilegeServer ControlLicense RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNoneBIOS.SysSecurity.Aesni (Read or Write)DescriptionDisplay

Pagina 320

• SysSecurity.TpmSecurity is not set to OnPbmBIOS.SysSecurity.NmiButton (Read or Write)DescriptionEnables or disables the NMI button on the front pane

Pagina 321

• Only lower case alphabets are accepted.• Special characters accepted are +, ",,, — , ., /, ;, [, \, ], `.To enable password modification, J_EN_

Pagina 322

BIOS.SysSecurity.TcmClear (Read or Write)DescriptionWarns that clearing the TPM causes loss of all keys in the TPM. It may affect starting the operati

Pagina 323

• Updates• Audit• Config• WorknotesValid Severity values are:• Critical• Warning• InfoValid examples of alert descriptors are:• idrac.alert.all• idrac

Pagina 324

License RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyRead Only if SysSecurity.TpmSecurity is set to Off.BIOS.SysSecurity.TpmSecurity (Read or

Pagina 325

• UnavailableWrite PrivilegeServer ControlLicense RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNoneNIC.DCBSettings.EnhancedTransmissionSelecti

Pagina 326

License RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNoneNIC.DeviceLevelConfig.FlowControlSetting (Read or Write)DescriptionConfigure type of

Pagina 327

NIC.FCOECapabilities.MaxFrameSize (Read Only)DescriptionIndicates the maximum frame size for each FCoE frame.Legal ValuesNoneWrite PrivilegeServer Con

Pagina 328

License RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNoneNIC.FCOECapabilities.MaxNumberOfFCTargets (Read Only)DescriptionIndicates the maximum

Pagina 329

Default ValueDisabledWrite PrivilegeServer ControlLicense RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNoneNIC.FCoEConfiguration.FirstFCoEBoot

Pagina 330

License RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNoneNIC.FCoEGenParamsThe following section provides information about the objects in the

Pagina 331

License RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNoneNIC.FCoEGenParams.FCoELnkUpDelayTime (Read or Write)DescriptionSpecifies the time FCo

Pagina 332

NIC.FrmwImgMenu.ControllerBIOSVersion (Read Only)DescriptionIndicates the controller BIOS version information.Legal ValuesString of up to 8 ASCII char

Pagina 333

NIC.GlobalBandwidthAllocation.MinBandwidth (Read or Write)DescriptionSet the minimum percentage of port TX bandwidth allocated to partition.Legal Valu

Pagina 334

feature...

Pagina 335

• Configure using severity as a parameter. For example, all informational events in storage category are assigned power off as action, and email and s

Pagina 336

License RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNot Available if VndrConfigGroup.iSCSIBootSupport is Unavailable.NIC.IscsiFirstTgtParams.

Pagina 337

NIC.IscsiGenParamsThe following section provides information about the objects in the NIC.IscsiGenParams group.NIC.IscsiGenParams.ChapAuthEnable (Read

Pagina 338

NIC.IscsiGenParams.FirstHddTarget (Read or Write)DescriptionEnables or disables to check if the iSCSI target appears as the first hard disk drive (HDD

Pagina 339

NIC.IscsiGenParams.IscsiViaDHCP (Read or Write)DescriptionEnables the acquisition of iSCSI target parameters from DHCP.Legal Values• Enabled• Disabled

Pagina 340

License RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNot Available if IscsiGenParams.IpVer is set to 'IPv6' and VndrConfigGroup.iSCS

Pagina 341

NIC.IscsiInitiatorParams.IscsiInitiatorChapPwd (Password)DescriptionSet the iSCSI initiator Challenge-Handshake Authentication Protocol (CHAP) secret

Pagina 342 - BIOS.BiosBootSettings

License RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNot available if VndrConfigGroup.iSCSIBootSupport is unavailable.NIC.IscsiInitiatorParams

Pagina 343 - BIOS.IntegratedDevices

DependencyNot available if VndrConfigGroup.iSCSIBootSupport is unavailable.NIC.IscsiSecondaryDeviceParams.UseIndTgtName (Read or Write)DescriptionSpec

Pagina 344

NIC.IscsiSecondTgtParams.SecondTgtBootLun (Read or Write)DescriptionSpecifies the second iSCSI storage target boot Logical Unit Number (LUN).Legal Val

Pagina 345

NOTE: The legal value range may be smaller than the maximum size of 223, based on the vendor configuration of the NIC cards.Write PrivilegeServer Cont

Pagina 346

NOTE: To deactivate FlexAddress features, the chassis must be turned off.Synopsisracadm feature -sracadm feature -d -c <featurename>racadm featu

Pagina 347

• 100 Mbps Half• 100 Mbps FullWrite PrivilegeServer ControlLicense RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNoneNIC.NICConfig.VLanId (Read

Pagina 348

NIC.NICConfig.WakeOnLanLnkSpeed (Read or Write)DescriptionSelect the port speed used for Wake on LAN mode.Legal Values• AutoNeg• 10 Mbps Half• 10 Mbps

Pagina 349 - BIOS.MemSettings

NIC.NICPartitioningConfig.NumberPCIEFunctionsSupported (Read Only)DescriptionIndicates the number of physical PCIe functions supported on this port.Le

Pagina 350

NIC.VndrConfigGroup.EnergyEfficientEthernet (Read Only)DescriptionIndicates whether Energy Efficient Ethernet capability is supported.Legal ValuesNone

Pagina 351

NIC.VndrConfigGroup.FCoEOffloadSupport (Read Only)DescriptionIndicates whether FCoE Offload capability is supported.Legal ValuesNoneWrite PrivilegeSer

Pagina 352

License RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNoneNIC.VndrConfigGroup.ISCSIMacAddr (Read Only)DescriptionIndicates the permanent MAC ad

Pagina 353 - BIOS.MiscSettings

NIC.VndrConfigGroup.MacAddr (Read Only)DescriptionIndicates the permanent MAC address assigned during manufacturing.Legal ValuesString of up to 17 cha

Pagina 354

NIC.VndrConfigGroup.OnChipThermalSensor (Read Only)DescriptionIndicates whether an on-chip thermal sensor is available.Legal ValuesNoneWrite Privilege

Pagina 355 - BIOS.OneTimeBoot

License RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNoneNIC.VndrConfigGroup.RXFlowControl (Read Only)DescriptionIndicates whether Receive (RX

Pagina 356 - BIOS.ProcSettings

NIC.VndrConfigGroup.TXFlowControl (Read Only)DescriptionIndicates whether Transmit (TX) Flow Control capability is supported.Legal ValuesNoneWrite Pri

Pagina 357

Output• No feature card inserted — Action: To verify that the SD card was properly inserted, check the CMC. In a redundant CMC configuration, make sur

Pagina 358

NIC.VndrConfigGroup.VirtualLinkControl (Read or Write)DescriptionIndicates whether Virtual Link Control capability is supported.Legal ValuesNoneWrite

Pagina 359

License RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNoneStorage.ControllerThe objects in this group manage storage controller attributes.The

Pagina 360

Dependency NoneStorage.Controller.CheckConsistencyRate (Read or Write)Description The Check Consistency rate is the percentage of the system's r

Pagina 361

Storage.Controller.EnhancedAutoImportForeignConfig (Read or Write)Description This property indicates the Enhanced Auto Import of Foreign Configuratio

Pagina 362

• DisabledDefault valueWrite Privilege Server ControlLicense RequirediDRAC7 Express or iDRAC7 EnterpriseDependency NoneStorage.Controller.RebuildRate

Pagina 363

Dependency NoneStorage.Controller.SupportEnhancedAutoForeignImport (Read Only)Description This is readonly attribute. This property indicates if this

Pagina 364

The following section provides information about the objects in this group.Storage.PhysicalDisk.BlockSizeInBytes (Read Only)Description This is readon

Pagina 365

• CapableDefault valueWrite Privilege Configure iDRACLicense RequirediDRAC7 Express or iDRAC7 EnterpriseDependency NoneStorage.VirtualDiskThe objects

Pagina 366

Storage.VirtualDisk.ReadPolicy (Read or Write)Description The read policies indicate whether or not the controller must read sequential sectors of the

Pagina 367 - BIOS.SataSettings

only be a single update operation in progress at any time. In addition, the fwupdate subcommand may only update one or more devices of a single kind a

Pagina 368

Input• —u — For iDRAC: The update option performs a checksum of the firmware update file and starts the actual update process. This option may be used

Pagina 369

NOTE: iDRAC7 targets are not supported from CMC. To update the iDRAC7 targets, use the CMC GUI.CMC version 3.00 accepts IPv4, IPv6 or fully qualified

Pagina 370

To block the firmware downgrade on 3000W AC power supply configuration.racadm fwupdate –s Ready for firmware update racadm fwupdate –g –u –a 10.210.13

Pagina 371

For the --clone and --replace options, check the Job ID by running the racadm jobqueue view command. For more information, see jobqueue.Synopsisracadm

Pagina 372

NOTE: For --clone and --replace options, only .xml file template is received. These options --clone and --replace cannot be used in the same command.E

Pagina 373

• cmc-n — where n=1, 2• fan-n — where n=1–9• ps-n — where n=1–6• chassis• kvm• lcdNOTE: A few of the informational messages are applicable for more th

Pagina 374

ping6...

Pagina 375

• To display entire information log.racadm getactiveerrors -s infoModule ID = server-1Severity = CriticalMessage = A fabric mismatch deteceted for mez

Pagina 376 - BIOS.SerialCommSettings

To run this subcommand, you must have the CMC Login User privilege.Synopsisracadm getassettag [-m <module>]Input -m <module> — Specifies t

Pagina 377 - BIOS.SlotDisablement

maximum number of indexes a particular group supports. If -i <index> is not specified, then a value of 1 is assumed for groups, which are tables

Pagina 378

getdcinfoDescription Displays general I/O module and daughter card configuration information. Only the CMC controls daughter cards.This subcommand is

Pagina 379

server-7 Not Present None N/A None N/Aserver-8 Present FibreChannel 4Invalid None N/Aserver-9 Extension(1) None N/A None N/Aserver-10 Not Present None

Pagina 380 - BIOS.SysInformation

getflexaddrDescription Displays enabled/disabled status for the entire chassis. If used with the -i option, the command displays MACs/WWN on a per slo

Pagina 381 - BIOS.SysProfileSettings

16 Enabled Not Presentidrac System DisabledDisplay the current flex address setting for slot 1.racadm getflexaddr -i 1 Slot-1 server presence = Presen

Pagina 382

Exampleracadm getfanreqinfo[Ambient Temperature Fan Request %]38[Server Module Fan Request Table]<Slot#> <Server Name><Blade Type>

Pagina 383

<Slot#> <Server Name><Blade Type> <Power State><Presence> <Fan Request%>1 SLOT-01 PowerEdgeM600ON Present 332 S

Pagina 384

Switch-4 N/A None Not Present N/ASwitch-5 N/A None Not Present N/A Switch-6 N/A None Not Present N/ADisplay Enhanced Cooling Mode status.racadm ge

Pagina 385 - BIOS.SysSecurity

Displayable Characters...

Pagina 386

<Chassis> <IO> <Slot> <Presence><Role> <Unit> <Stack ID>JP4BF2S Switch-1 A1 Present Master N/A N/AJP4BF2S Sw

Pagina 387

getledDescription Displays the LED settings on a module: blinking, not blinking, or unknown (for empty slots).To run this subcommand, you must have th

Pagina 388

• -x — Displays the extra MACs (Ethernet or iSCSI) for servers with extra LOM MACs and must be used with -m option.• -a — Displays the Ethernet and iS

Pagina 389

Server-5 Present 14:FE:B5:00:F0:B414:FE:B5:00:F0:B514:FE:B5:00:F0:B7Server-6 Not Present Not Installed Not Installed Not InstalledServer-7 Present 14:

Pagina 390 - NIC.DCBSettings

Gigabit EthernetPresent 14:FE:B5:00:F0:8314:FE:B5:00:F0:84Server-1-B Gigabit EthernetPresent 14:FE:B5:00:F0:8514:FE:B5:00:F0:86Gigabit EthernetPresent

Pagina 391 - NIC.DeviceLevelConfig

iSCSI Present 00:21:9B:FE:39:C100:21:9B:FE:39:C3Server-5-B Gigabit EthernetPresent 14:FE:B5:00:F0:B914:FE:B5:00:F0:BBiSCSI Present 00:10:18:49:EF:1900

Pagina 392 - NIC.FCOECapabilities

Server-9-A Gigabit Ethernet Present 14:FE:B5:00:F0:E814:FE:B5:00:F0:E914:FE:B5:00:F0:EAGigabit Ethernet Present 14:FE:B5:00:F0:EB14:FE:B5:00:F0:ECSe

Pagina 393

Server-14 Not Installed Not Present Not InstalledNot InstalledNot InstalledServer-15 Not Installed Not Present Not InstalledNot InstalledNot Installed

Pagina 394 - NIC.FCoEConfiguration

– fpc-cable• -A — Suppresses headers and labels in the output.Examples• racadm getmodinfo -m switch-1<module> <presence> <pwrState>

Pagina 395

Server-6 Present ON OK 1234567Server-7 Present ON OKServer-8 Not Present N/A N/A N/AServer-9 Not Present N/A N/A N/AServer-10 Extension(2) N/A N/A N/A

Pagina 396 - NIC.FCoEGenParams

cfgVFlashPartition...

Pagina 397 - NIC.FrmwImgMenu

IPv4 settings:NIC Enabled = 1IPv4 Enabled = 1DHCP Enabled = 1IP Address = 10.35.0.64Subnet Mask = 255.255.255.0Gateway = 10

Pagina 398 - NIC.GlobalBandwidthAllocation

getpbinfoDescription Displays power budget status information.This subcommand is applicable only for CMC.To run this subcommand, you must have the CMC

Pagina 399 - NIC.IscsiFirstTgtParams

2 SLOT-02 OFF 0 W 5 PowerEdgeM8053 SLOT-03 ON 164 W 5 N/A4 SLOT-04 ON 155 W 55 SLOT-05 ON 180 W 56 SLOT-06 ON 180 W 5 PowerEdgeM6007 SLOT-07 ON 170 W

Pagina 400

System Potential Power = 68 W (188 BTU/hr)System Input Current Reading = 31.2 A[Real-Time Energy Statistics]System Energy Consumption = 6.4 kWhSystem

Pagina 401 - NIC.IscsiGenParams

Example• Display the starting record and the number of records.racadm getraclog -s 10 -c 2• Display a few records and prompt to display another set of

Pagina 402

getredundancymodeDescription Displays the redundancy status (Redundant or Non-Redundant) of the CMC.This subcommand is applicable only for CMC.To run

Pagina 403

Examples:For CMC:racadm getsensorinfo<senType> <Num> <sensorName><status> <reading> <units> <lc> <uc>F

Pagina 404 - NIC.IscsiInitiatorParams

System Board Exhaust TempOk 25 C 3 C 75 CCPU1 Temp Unknown NA NA NASensor Type : FAN<Sensor Name> <Status> <Reading> <lc> <

Pagina 405

CPU1 PLL PG Ok Good NA NASystem Board 1.1V PGOk Good NA NACPU1 M23 VDDQ PG Ok Good NA NACPU1 M23 VTT PGOk Good NA NASystem Board FETDRV PGOk Good NA N

Pagina 406

DIMM SLOT A2 N/A Absent NA NADIMM SLOT A3 N/A Absent NA NA<Sensor Name> <Status> <State> <lc> <uc>DIMM SLOT A1 Ok Presen

Pagina 408

<Sensor Name> <Intrusion> <Status>System Board Intrusion Closed Power ONSensor Type : REDUNDANCY<Sensor Name> <Status> &

Pagina 409 - NIC.NICConfig

14 SLOT-14 15 SLOT-15 16 SLOT-16racadm getslotname -i 1Webserver-1getssninfoDescriptionDisplays a list of users that are connect

Pagina 410

getsysinfoDescriptionDisplays information related to iDRAC, CMC, managed system, and watchdog configuration.NOTE: The local racadm getsysinfo subcomma

Pagina 411 - NIC.NICPartitioningConfig

Enabled = 0Current IP Address 1 = ::Current IP Gateway = ::Autoconfig = 1Link Local IP Address = ::Current IP A

Pagina 412 - NIC.VndrConfigGroup

Host Name =OS Name =OS Version =Power Status = ONFresh Air Capable = YesWatchdog Informati

Pagina 413

• racadm getversion -l [-m <module>] [-f <filter>]• racadm getversionInput• (none) — Displays the version information for all targets or d

Pagina 414

server-2 1.0.3 PowerEdgeM610xserver-4 1.0.0 PowerEdgeM710HDserver-5 1.0.3 PowerEdgeM710server-7 1.0.6 PowerEdgeM620server-9 1.0.5 PowerEdgeM520<Swi

Pagina 415

switch-5 Dell PowerConnect M6348 X02switch-6 Dell PowerConnect M6220 A01racadm getversion -l -m server-1<Server> <Component> <Version&g

Pagina 416

NIC-PERC S110 Controller3.0.0-0139 2012-10-11RAID-PERC H310 Mini 20.10.1-0084 Reinstall RAID-PERC H310 Mini 20.10.1-0084 Reinstall RAID-PERC H310

Pagina 417

NIC FQDD "NIC.Slot.5-1-2" AvailableNIC FQDD "NIC.Slot.5-1-3" AvailableNIC FQDD "NIC.Slot.5-1-4" AvailableTo display the

Pagina 418

NIC.IscsiSecondTgtParams...

Pagina 419

PCI Sub Vendor ID: 1077PCI Device ID: 2532PCI Sub Device ID: 015c

Pagina 420

Fabric Login Retry Count: 0Fabric Login Timeout: 0Port Login Retry Count: 8Port Logi

Pagina 421 - Storage.Controller

InputOptions for:racadm inlettemphistory exportSubcommand:• -f — Exports inlet temperature history filename. The maximum length of this parameter is 6

Pagina 422

NOTE: To run this subcommand, you must have the Server Profile Export and Import license.Synopsisracadm jobqueue view -i<jobid>where valid optio

Pagina 423

Input -f — Specifies the filename of the keytab uploaded. If the file is not specified, the keytab file in the current directory is selected.Output Re

Pagina 424

– DE– WSMAN– RACADM– iDRAC_GUI• -c — The category used to filter the records. Provides multiple categories using a "," as the delimiter. The

Pagina 425 - Storage.PhysicalDisk

– RemoteUpdate– OsDeployment– USC– Other• —m <Comment> — User comment string for a record that must be inserted in the Lifecycle Controller log.

Pagina 426

• Export the complete Lifecycle log in gzip format to a remote CIFS share. racadm lclog export -f log.xml.gz -u admin -p mypass -l //10.94.161.103/sh

Pagina 427 - Storage.VirtualDisk

• -o — Overrides the End User License Agreement (EULA) warning and imports, replaces or deletes the license.NOTE: For license operations, <license

Pagina 428

• Export license to an NFS share using transaction ID, in this case transaction 27.racadm license export -f License.xml -l 192.168.2.140:/licshare-t 2

Comentarios a estos manuales

Sin comentarios