Switch-4 N/A None Not Present N/A
Switch-5 N/A None Not Present N/A
Switch-6 N/A None Not Present N/A
Display Enhanced Cooling Mode status.
racadm getfanreqinfo
[Enhanced Cooling Mode]
Enhanced Cooling Mode(ECM) Status = Disabled
getioinfo
Description Displays general information about the I/O modules on the chassis.
This subcommand is applicable only for CMC.
To run this subcommand, you must have the CMC Login User privilege.
NOTE: The fabric type may be any supported I/O fabric type, such as Ethernet, Fibre Channel,
and InfiniBand.
Synopsis
racadm getioinfo [-m <module>] [-s]
Input
-m <module> — Specifies the module or device.<module> must be switch — <n>, where n
= 1–6
-s — Displays stack information.
Example
racadm getioinfo
<IO> <Name> <Type> <Presence
>
<POST> <Power> <Role>
switch-1 Dell
Ethernet
Passthrou
gh
Gigabit
Ethernet
Present OK ON Master
switch-2 N/A None Not
Present
N/A N/A N/A
switch-3 Brocade
4424
Fibre
Channel 4
Present OK ON Master
switch-4 N/A None Not
Present
N/A N/A N/A
switch-5 N/A None Not
Present
N/A N/A N/A
switch-6 N/A None Not
Present
N/A N/A N/A
racadm getioinfo -s
59
Vista de pagina 58