Dell Chassis Management Controller Version 4.50 Guía de usuario Pagina 293

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 428
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 292
License
Required
iDRAC7 Express or iDRAC7 Enterprise
Dependency
Cannot be Enabled unless IPv6.AutoConfig is enabled.
iDRAC.IPv6.Enable (Read or Write)
Description
Enables or Disables iDRAC IPv6 stack.
Legal Values
0 — Disabled
1 — Enabled
Default Value
0 — Disabled
Write Privilege
Configure iDRAC
License
Required
iDRAC7 Express or iDRAC7 Enterprise
Dependency
None
iDRAC.IPv6.Gateway (Read or Write)
Description
iDRAC IPv6 Gateway
Legal Values
Valid IPv6 gateway
Write Privilege
Configure iDRAC
License
Required
iDRAC7 Express or iDRAC7 Enterprise
Dependency
Cannot be set unless IPv6.AutoConfig is disabled.
iDRAC.IPv6.LinkLocalAddress (Read or Write)
Description
iDRAC IPv6 Link Local Address.
Legal Values
Valid IPv6 Address
Write Privilege
Configure iDRAC
License
Required
iDRAC7 Express or iDRAC7 Enterprise
Dependency
None
iDRAC.IPv6.PrefixLength (Read or Write)
Description
Prefix length for the iDRAC IPv6 Address.
Legal Values
Integral values: 1–128
Default Value
64
Write Privilege
Configure iDRAC
293
Vista de pagina 292
1 2 ... 288 289 290 291 292 293 294 295 296 297 298 ... 427 428

Comentarios a estos manuales

Sin comentarios