Dell Chassis Management Controller Version 4.50 Guía de usuario Pagina 160

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 428
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 159
Default
<blank>
cfgRhostsSyslogPowerLoggingEnabled
Description To remote syslog servers, Enables or disables power consumption logging.
This object is applicable only for CMC.
NOTE: Remote syslog must be enabled and more than one remote syslog servers must be
configured to log the power consumption.
Legal Values
1 (enabled)
0 (disabled)
Default
0
cfgRhostsSyslogPowerLoggingInterval
Description Specifies the power consumption collection/logging interval.
This object is applicable only for CMC.
NOTE: This object is applicable only for CMC.
Legal Values
1–1440 (minutes)
Default
5
Example
racadm getconfig -g cfgRemoteHosts [-m server-<n>]
cfgRhostsFwUpdateTftpEnable=1
cfgRhostsFwUpdateIpAddr=0.0.0.0
cfgRhostsFwUpdatePath=
cfgRhostsSmtpServerIpAddr=localhost.localdomain
cfgRhostsNtpEnable=0
cfgRhostsNtpServer1=
cfgRhostsNtpServer2=
cfgRhostsNtpServer3=
cfgRhostsNtpMaxDist=16
cfgRhostsSyslogEnable=0
cfgRhostsSyslogPort=514
cfgRhostsSyslogServer1=
cfgRhostsSyslogServer2=
cfgRhostsSyslogServer3=cfgRhostsSyslogPowerLoggingEnabled=1
cfgRhostsSyslogPowerLoggingInterval=5
cfgUserAdmin
This group provides configuration information about the users who are allowed to access iDRAC or CMC through the
available remote interfaces.
Up to 16 instances of the user group are allowed. Each instance represents the configuration for an individual user.
160
Vista de pagina 159
1 2 ... 155 156 157 158 159 160 161 162 163 164 165 ... 427 428

Comentarios a estos manuales

Sin comentarios