2 SLOT-02 OFF 0 W 5 PowerEdgeM80
5
3 SLOT-03 ON 164 W 5 N/A
4 SLOT-04 ON 155 W 5
5 SLOT-05 ON 180 W 5
6 SLOT-06 ON 180 W 5 PowerEdgeM60
0
7 SLOT-07 ON 170 W 5
8 SLOT-08 N/A N/A 5 N/A
9 SLOT-09 N/A N/A 5 N/A
10 SLOT-10 Extension(2) N/A 5 N/A
11 SLOT-11 N/A N/A 5 N/A
12 SLOT-12 ON 125 W 5 PowerEdgeM60
0
13 SLOT-13 N/A N/A 5 N/A
14 SLOT-14 ON 342 W 5 N/A
15 SLOT-15 ON 140 W 5
16 SLOT-16 ON 125 W 5 N/A
NOTE: Extended Power Performance (EPP) – related fields are displayed even if EPP is disabled.
getpminfo
Description Displays power management status information.
This subcommand is applicable only for CMC.
To run this subcommand, you must have the CMC Login User privilege.
Synopsis
racadm getpminfo
Example:
racadm getpminfo
[Real-Time Power Statistics]
System Input Power = 600 W (188 BTU/hr)
Peak System Power = 600 W (188 BTU/hr)
Peak System Power Start Time = 16:02:10 01/16/2008
Peak System Power Timestamp = 06:32:55 01/26/2009
Minimum System Power = 400 W (177 BTU/hr)
Minimum System Power Start Time = 22:43:21 01/21/2008
Minimum System Power Timestamp = 06:32:55 01/26/2009
System Idle Power = 68 W (188 BTU/hr)