Examples
racadm getconfig -g cfgAlerting -o cfgAlertingSourceEmailName
racadm config -g cfgAlerting -o cfgAlertingSourceEmailName [email protected]
Object value modified successfully.
cfgLcdLocale
Description
Specifies the Language (locale) for the Blade Chassis LCD interface.
Legal Values
de, fr, en, es, ja, zh-cn.
Default
en
Example
racadm config -g cfgLcdInfo -o cfgLcdLocale en
Object value modified successfully.
cfgServerPowerSupply
This group contains information related to the power supplies.
The cfgServerPowerSupply object group is applicable only for iDRAC on Rack and Tower Servers and not for iDRAC
Enterprise on Blade Servers.
NOTE: The getconfig subcommand always shows eight cfgServerPowerSupply indexes, even if two power supplies
are installed in the system or the system supports a maximum of two PSUs. For the uninstalled and unsupported
units, all the objects in the
cfgServerPowerSupply group displays a value of 0.
The following sections provide information about the objects in the cfgServerPowerSupply group.
cfgServerPowerSupplyIndex
Description
Specifies index of the PSU.
NOTE: Indexes 1–8 are supported to support up to 8 PSUs. If any PSU is not present then
cfgServerPowerSupplyOnlineStatus does not exist and for all the other properties, it is 0.
Legal Values
Integer 1–8
Default
None
cfgServerPowerSupplyMaxInputPower (Read Only)
Description
Displays the AC input rated power in Watts.
Legal Values
A string of up to 32 characters.
Default
0
221