Dell Chassis Management Controller Version 4.50 Guía de usuario Pagina 284

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 428
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 283
4—Administrator
Default Value 4—Administrator
Write Privilege Configure iDRAC
License
Required
iDRAC7 Express or iDRAC7 Enterprise
Dependency None
iDRAC.IPMISOL.SendThreshold (Read or Write)
Description To buffer before sending an SOL data packet, specifies the SOL threshold limit value and the
maximum number of bytes
Legal Values Integral values: 1–255
Write Privilege Configure iDRAC
License
Required
iDRAC7 Express or iDRAC7 Enterprise
Dependency None
iDRAC.IPv4
To manage the IPv4 configuration properties of iDRAC, use these objects in this group.
iDRAC.IPv4.Address (Read or Write)
Description
The current IPv4 address assigned to iDRAC.
Legal Values
Valid IPv4 Address
`
Default Value
192.168.0.120
Write Privilege
Configure iDRAC
License
Required
iDRAC7 Express or iDRAC7 Enterprise
Dependency
Cannot be set unless IPv4.DHCPEnable is disabled.
iDRAC.IPv4.DHCPEnable (Read or Write)
Description
Specifies if DHCP is used to assign the iDRAC IPv4 address.
Legal Values
0 — Disabled
1 — Enabled
Default Value
0 — Disabled
Write Privilege
Configure iDRAC