System.Power.Cap.MaxThreshold (Read Only)
Description
Because it is based on the current component inventory, it has maximum server power capacity.
Legal Values
Values: 1–65535
Write Privilege
Configure iDRAC
License
Required
iDRAC7 Express or iDRAC7 Enterprise
Dependency
None
System.Power.Cap.MinThreshold (Read Only)
Description
Because it is based on the current component inventory, it is the lowest calculated power
consumption of the device.
Legal Values
Values: 1–65535
Write Privilege
Configure iDRAC
License
Required
iDRAC7 Express or iDRAC7 Enterprise
Dependency
None
System.Power.Cap.Percent (Read or Write)
Description
Represents the maximum power as a percentage of total power that a server is allowed to consume.
To meet this cap, throttle the device.
NOTE: This value is read only for Modular servers.
NOTE: This value is applicable only if System.Power.Cap.Enable is set to 1.
Legal Values
Values: 0–100
Default Value
Server power threshold in percentage.
Write Privilege
Configure iDRAC
License
Required
iDRAC7 Express or iDRAC7 Enterprise
Dependency
EnableSystem.Power.Cap.Enable
System.Power.Redundancypolicy
Description Selects the redundancy policy.
Legal Values
N/A
Not Redundant — In this mode, even if one PSU stops functioning, the server is
automatically turned off.