Default
0 — (disabled)
cfgChassisAllow110VACOperation (Read or Write)
Description Enables or disables normal chassis power allocations when any PSU is connected to 110 V AC
service. If disabled and 110 V power supplies are detected, all subsequent server power allocation
requests are denied. In this mode more servers cannot be powered on, regardless of server priority.
Legal Values
• 0 (disabled)
• 1(enabled)
Default
0(disabled)
—
cfgChassisMaxPowerConservationMode (Read or Write)
Description
Enables or disables maximum power conservation mode. When enabled, all servers are immediately
reduced to their minimum power levels, and all subsequent server power allocation requests are
denied. In this mode, performance of powered on servers may be degraded and more servers
cannot be powered on, regardless of server priority.
Legal Values
• 0(disabled)
• 1(enabled)
Default
0(disabled)
cfgChassisPerformanceOverRedundancy (Read or Write)
Description
Enables or disables server performance over power redundancy. When enabled, this option favors
server performance and server power-up over maintenance of power redundancy. When disabled,
the system favors power redundancy over server performance. If the power supplies in the chassis
do not provide sufficient power, both for redundancy, as well as full performance, then some servers
may not grant sufficient power for full performance. In order to maintain redundancy, It may not be
powered on.
Legal Values
• 0(disabled)
• 1(enabled)
Default
1 (enabled)
cfgChassisInMaxPowerCapacity (Read Only)
Description
Indicates the total chassis power budget (in watts) available for chassis operation.
Legal Values
None
Default
None