Default Value
0 — not applicable
System.Power.RedundantState (Read Only)
Description
Retrieves the redundancy state for the chassis.
Legal Values
0 — None
1 — Full
Default 0 — None
System.Power.Supply
This group provides information relating to the Power Supplies.
This group is indexed from 1 to 4. If there are less than four power supplies on the server, then some of the last indexes
of this group are not applicable. This group is not applicable for iDRAC on Rack and Tower servers.
The following section provides information about the objects in this group.
System.Power.Supply.CurrentDraw (Read Only)
Description
Displays the instantaneous current consumption in 0.1 amps.
Legal Values
String of up to 254 ASCII characters
Write Privilege
Configure iDRAC
License
Required
iDRAC7 Express or iDRAC7 Enterprise
Dependency
None
System.Power.Supply.FwVer (Read Only)
Description
Displays the firmware version of the PSU.
Legal Values
String up to 254 ASCII characters.
Write Privilege
Configure iDRAC
License
Required
iDRAC7 Express or iDRAC7 Enterprise
Dependency
None
System.Power.Supply.[i].MaxInputPower (Read Only)
Description
Displays the AC input rated power in Watts.
Legal Values
Integer > 0
Default
0