Dell Chassis Management Controller Version 4.50 Guía de usuario Pagina 342

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 428
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 341
iDRAC.WebServer.LowerEncryptionBitLength (Read or Write)
Description
Lower Encryption Bit Length.
Legal Values
0 — Disabled (Auto Negotiate)
1 — Enabled (12 Bit or Higher)
Default Value
1 — Enabled (128 Bit or Higher)
Write Privilege
Configure iDRAC
License
Required
iDRAC7 Express or iDRAC7 Enterprise
Dependency
None
iDRAC.WebServer.Timeout (Read or Write)
Description
Defines the webserver timeout.
Legal Values
Integral values: 60–10800
Default Value
1800
Write Privilege
Configure iDRAC
License
Required
iDRAC7 Express or iDRAC7 Enterprise
Dependency
None
BIOS.BiosBootSettings
You can manage the BIOS start settings using the objects in this group.
BIOS.BiosBootSettings.BootSeq (Read or Write)
Description
Determines the Bios start sequence of the system.
Legal Values
None
Write Privilege
Server Control
License
Required
iDRAC7 Express or iDRAC7 Enterprise
Dependency
Read Only if BootMode is set to UEFI
BIOS.BiosBootSettings.BootMode (Read or Write)
Description
Determines the start mode of the system.
Legal Values
BIOS
UEFI
342
Vista de pagina 341
1 2 ... 337 338 339 340 341 342 343 344 345 346 347 ... 427 428

Comentarios a estos manuales

Sin comentarios