Dell Chassis Management Controller Version 4.50 Guía de usuario Pagina 345

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 428
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 344
License
Required
iDRAC7 Express or iDRAC7 Enterprise
Dependency
None
BIOS.IntegratedDevices.EmbNic3Nic4 (Read or Write)
Description
Enables or disables the operating system interface of the embedded NIC3 and NIC4 controllers.
Legal Values
Enabled
Disabled OS
Disabled
Write Privilege
Server Control
License
Required
iDRAC7 Express or iDRAC7 Enterprise
Dependency
None
BIOS.IntegratedDevices.EmbNic4 (Read or Write)
Description
Enables or disables the operating system interface of the embedded NIC4.
Legal Values
Enabled
EnabledPxe
EnablediScsi
Disabled
Write Privilege
Server Control
License
Required
iDRAC7 Express or iDRAC7 Enterprise
Dependency
None
BIOS.IntegratedDevices.EmbVideo (Read or Write)
Description
Enables or disables the BIOS support for the embedded video controller.
Legal Values
Enabled
Disabled
Write Privilege
Server Control
License
Required
iDRAC7 Express or iDRAC7 Enterprise
Dependency
None
345