<Sensor Name> <Intrusion> <Status>
System Board Intrusion Closed Power ON
Sensor Type : REDUNDANCY
<Sensor Name> <Status> <Type>
System Board Fan
Redundancy
Full Redundant Fan
System Board PS
Redundancy
Disabled PSU
Sensor Type : SD CARD
<Sensor Name> <State>
vFlash Active
getslotname
Description
Displays the name and host name (if available) of all 16 slots, or of a specified slot (the slot number is
indicated) in the chassis. Optionally, this command can be used to find if the slot name or host name
is displayed in the CMC User Interface or with the getslotname —i <slot ID> command. If
the host name is not available, the static slot name is used.
This subcommand is applicable only for CMC.
To use this subcommand, you must have the CMC Login User privilege.
Synopsis
racadm getslotname
racadm getslotname -i <slot ID>
racadm getslotname -h
Input
racadm getslotname — Displays the slot name for all 16 slots in the chassis.
-i <slot ID> — specifies the ID of the slot.
Legal values: 1–16
-h — Specifies whether to use the slot name or the host name (if available).
1= use host names, 0=use slotnames
Example
racadm getslotname
<
Slot #
> <
Slot Name
> <
Host name
>
1 SLOT-01
2 Webserver01 WXP-8GRB221
3 Webserver3 WXP-319QWEecet5
4 SLOT-04
5 SLOT-05
6 SLOT-06
7 SLOT-07
8 SLOT-08
9 SLOT-09
10 SLOT-10
11 SLOT-11
12 SLOT-12
13 SLOT-13