getled
Description Displays the LED settings on a module: blinking, not blinking, or unknown (for empty slots).
To run this subcommand, you must have the Login User privilege.
Synopsis
racadm getled -m <module>
Input For CMC:
-m <module> — Specifies the module whose LED settings you want to view.
<module> can be one of the following:
server–nx where n=1–8; x=a, b, c, d
switch–n where n=1–6
chassis
cmc-active
Output None
Example For CMC:
racadm getled -m server-10
<module> <LED state> server-10 Blinking
racadm getled -m chassis
<module> <LED state> server-10 Not blinking
racadm getled -m server-1
<module> <LED state> server-1 ON
racadm getled -m server-9
<module> <LED state> server-9 Extension(1)
For iDRAC:
racadm getled
LED is blinking
getmacaddress
Description Displays the MAC/WWN addresses for all modules or for a specified module.
This subcommand is applicable only for CMC.
To run this subcommand, you must have the CMC Login User privilege.
Synopsis
racadm getmacaddress [-m <module>] [-t iscsi] [-x]
racadm getmacaddress [-a]
Input
-m <module> — Specifies the module whose MAC address you want to view.
<module> may be one of the following:
server-nx where n= 1–8;
x
= a, b, c, d
switch-n where n=1–6
-t — Displays the iSCSI MAC addresses for all servers or the specified server if used with -m
option.