cfgRemoteHosts
This group provides properties that allow configuration of the SMTP server for email alerts.
For CMC, this group enables/disables and configures firmware updates, NTP, remote syslogging and SMTP email
alerting. To apply this setting to iDRAC, use the —m option.
Use this object with the config or getconfig subcommands.
To use this object property for CMC, you must have the Chassis Configuration Administrator privilege.
The following sections provide information about the objects in the cfgRemoteHosts group.
cfgRhostsFwUpdateTftpEnable (Read or Write)
Description
Enables or disables iDRAC or CMC firmware update from a network TFTP server.
Legal Values
• 1 (TRUE)
• 0 (FALSE)
Default
1
cfgRhostsFwUpdateIpAddr (Read] or Write)
Description
Specifies the network TFTP server IPv4 or IPv6 address that is used for TFTP iDRAC or
CMC firmware update operations.
Legal Values
A string representing a valid IPv4 or IPv6 address. For example, 192.168.0.61
Default
For IPv4, it is 0.0.0.0
cfgRhostsFwUpdatePath (Read or Write)
Description
Specifies TFTP path where iDRAC or CMC firmware image file exists on the TFTP server. The TFTP
path is relative to the TFTP root path on the TFTP server.
NOTE: The server may still require you to specify the drive (for example, C:).
Legal Values
A string with a maximum length of 255 ASCII characters.
Default
<blank>
cfgRhostsSmtpServerIpAddr (Read or Write)
Description
The IPv4 or IPv6 address of the network SMTP server. The SMTP server transmits email alerts from
iDRAC or CMC if the alerts are configured and enabled.
Legal Values
A string representing a valid SMTP server IPv4 or IPv6 address. For example: 192.168.0.55.
Default
• For iDRAC: For IPv4, it is 0.0.0.0
• For CMC: localhost.localdomain