Dell Chassis Management Controller Version 4.50 Guía de usuario Pagina 233

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 428
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 232
cfgCurrentIPv6DNSServer2
Description
Displays the IPv6 address for DNS server 2.
Legal Values
None
Default
None
Example
racadm getconfig -g cfgCurrentIPv6LanNetworking
# cfgCurrentIPv6Enabled=1
# cfgCurrentIPv6AutoConfigWasUsed=1
# cfgCurrentLinkLocalAddress=fe80::21e:4fff:fe1f:5371/64
# cfgCurrentIPv6Address1=2009:123::e48f:9dd8:6f51:a669/64
# cfgCurrentIPv6Address2=fd88:1::21e:4fff:fe1f:5371/64
# cfgCurrentIPv6Address3=fd88:2::21e:4fff:fe1f:5371/64
# cfgCurrentIPv6Gateway=fe80::21c:23ff:fe77:6215
# cfgCurrentIPv6DNSServersFromDHCP6=1
# cfgCurrentIPv6DNSServer1=2009:123::1
# cfgCurrentIPv6DNSServer2=::
cfgIPv6URL
This group specifies properties used to configure iDRAC IPv6 URL.
This group is applicable only for iDRAC.
The following sections provide information about the objects in the cfgIPv6URL group.
cfgIPv6URLstring (Read Only)
Description
The iDRAC IPv6 URL.
Legal Values
A string of up to 80 characters.
Default
<blank>
cfgIpmiSerial
This group specifies properties used to configure the IPMI serial interface of the BMC.
It is applicable only for iDRAC on Rack and Tower Servers and not for iDRAC Enterprise on Blade Servers or CMC.
cfgIpmiSerialBaudRate (Read or Write)
Description
Specifies the baud rate for a serial connection over IPMI.
Legal Values
9600, 19200, 57600, 115200
Default
57600
233
Vista de pagina 232
1 2 ... 228 229 230 231 232 233 234 235 236 237 238 ... 427 428

Comentarios a estos manuales

Sin comentarios